    Schematic of N-type degenerate two-level system
    Fig. 1. Schematic of N-type degenerate two-level system
    Signal transmission spectra under different Rabi frequencies of pumping light
    Fig. 2. Signal transmission spectra under different Rabi frequencies of pumping light
    Gain peak amplitude of signal light versus Rabi frequency of pumping light under different Doppler widths
    Fig. 3. Gain peak amplitude of signal light versus Rabi frequency of pumping light under different Doppler widths
    Gain profiles of signal light under different Rabi frequencies of pumping light when Doppler shift (δD=0) is not considered. (a1) Ωp=0.70 MHz; (a2) Ωp=0.83 MHz; (a3) Ωp=0.94 MHz; (b1) Ωp=20 MHz; (b2) Ωp=7.06 MHz; (b3)Ωp=4.9 MHz
    Fig. 4. Gain profiles of signal light under different Rabi frequencies of pumping light when Doppler shift (δD=0) is not considered. (a1) Ωp=0.70 MHz; (a2) Ωp=0.83 MHz; (a3) Ωp=0.94 MHz; (b1) Ωp=20 MHz; (b2) Ωp=7.06 MHz; (b3)Ωp=4.9 MHz
    Gain profile variation of signal light when Doppler shift and broadening effects are included. (a) Ωp=10 MHz; (b) Ωp=150 MHz
    Fig. 5. Gain profile variation of signal light when Doppler shift and broadening effects are included. (a) Ωp=10 MHz; (b) Ωp=150 MHz
    Schematic of experimental setup
    Fig. 6. Schematic of experimental setup
    Experimentally measured gain peak amplitudes of signal light under different pumping powers when Ps=50 μW, Δp=0, and T=95 ℃. (a) Pp=10 mW; (b) Pp=70 mW
    Fig. 7. Experimentally measured gain peak amplitudes of signal light under different pumping powers when Ps=50 μW, Δp=0, and T=95 ℃. (a) Pp=10 mW; (b) Pp=70 mW
    Gain peak amplitude of signal light with different parameters. (a) Pumping power; (b) temperature
    Fig. 8. Gain peak amplitude of signal light with different parameters. (a) Pumping power; (b) temperature
    Influence of signal light polarization state on gain peak amplitude
    Fig. 9. Influence of signal light polarization state on gain peak amplitude