• Chinese Journal of Lasers
  • Vol. 47, Issue 3, 311001 (2020)
Dong Hewei, Guo Ruimin*, Cui Wenchao, and Li Dong
Author Affiliations
  • Environmental Measurement Center, National Institute of Metrology, Beijing 100029, China
  • show less
    DOI: 10.3788/CJL202047.0311001 Cite this Article Set citation alerts
    Dong Hewei, Guo Ruimin, Cui Wenchao, Li Dong. Cavity Ring-Down Spectroscopy Based on Folded Cavity[J]. Chinese Journal of Lasers, 2020, 47(3): 311001 Copy Citation Text show less
    References

    [1] Guo R M, Teng J H, Cao K et al. Comb-assisted, Pound-Drever-Hall locked cavity ring-down spectrometer for high-performance retrieval of transition parameters[J]. Optics Express, 27, 31850-31863(2019).

    [2] Cygan A, Wójtewicz S, Zaborowski M et al. One-dimensional cavity mode-dispersion spectroscopy for validation of CRDS technique[J]. Measurement Science and Technology, 27, 045501(2016).

    [3] O'Keefe A. Deacon D A G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J]. Review of Scientific Instruments, 59, 2544-2551(1988).

    [4] Cao K, Zhang G C, Guo R M et al[J]. Measurement technique of gas composition based on cavity ring-down spectroscopy Measurement Technique, 2017, 7-11.

    [5] Gong Y, Li B C. Broadband continuous-wave cavity ring-down technique with combined cavity configurations for high reflectivity measurement[J]. Chinese Journal of Lasers, 34, 857-860(2007).

    [6] Stancu D, Kaddouri F, Lacoste A et al. Atmospheric pressure plasma diagnostics by OES, CRDS and TALIF[J]. Journal of Physics D: Applied Physics, 43, 124002(2010).

    [7] Assaf E, Sheps L, Whalley L et al. The reaction between CH3O2 and OH radicals: product yields and atmospheric implications[J]. Environmental Science & Technology, 51, 2170-2177(2017).

    [8] Banik G D, Som S, Maity A et al. An EC-QCL based N2O sensor at 5.2 μm using cavity ring-down spectroscopy for environmental applications[J]. Analytical Methods, 9, 2315-2320(2017).

    [9] Mi Y P, Wang X P, Zhan S Y. Review on cavity ring down spectroscopy technology and its application[J]. Optical Instruments, 29, 85-89(2007).

    [10] Zellweger C, Emmenegger L, Firdaus M et al. Assessment of recent advances in measurement techniques for atmospheric carbon dioxide and methane observations[J]. Atmospheric Measurement Techniques, 9, 4737-4757(2016).

    [11] Kou X W, Zhou B, Liu X C et al. Measurement of trace NH3 concentration in atmosphere by cavity ring-down spectroscopy[J]. Acta Optica Sinica, 38, 1130001(2018).

    [12] Flores E, Rhoderick G C, Viallon J et al. Methane standards made in whole and synthetic air compared by cavity ring down spectroscopy and gas chromatography with flame ionization detection for atmospheric monitoring applications[J]. Analytical Chemistry, 87, 3272-3279(2015).

    [13] Wang D, Hu R Z, Xie P H et al. Measurement of nitrogen pentoxide in nocturnal atmospheric based on cavity ring-down spectroscopy[J]. Acta Optica Sinica, 37, 0901001(2017).

    [14] Tan Z Q, Long X W. A developed optical-feedback cavity ring-down spectrometer and its application[J]. Applied Spectroscopy, 66, 492-495(2012).

    [15] Brown S S. Absorption spectroscopy in high-finesse cavities for atmospheric studies[J]. Chemical Reviews, 103, 5219-5238(2003).

    [16] Fang S X, Zhou L X, Zang K P et al. Measurement of atmospheric CO2 mixing ratio by cavity ring-down spectroscopy (CRDS) at the 4 background stations in China[J]. Acta Scientiae Circumstantiae, 31, 624-629(2011).

    [17] Wilkinson J, Bors C, Burgis F et al. Correction: measuring CO2 and CH4 with a portable gas analyzer: closed-loop operation, optimization and assessment[J]. PLoS One, 14, e0206080(2019).

    [18] Sahay P, Scherrer S T, Wang C. A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: initial test with elemental Hg[J]. Review of Scientific Instruments, 83, 095109(2012).

    [19] Jiang X, Zong D R, Sun Z H et al. Study on acousto-optic modulator in laser display[J]. Optical Instruments, 29, 50-54(2007).

    [20] Krevor S, Perrin J C, Esposito A et al. Rapid detection and characterization of surface CO2 leakage through the real-time measurement of δ 13 C signatures in CO2 flux from the ground[J]. International Journal of Greenhouse Gas Control, 4, 811-815(2010).

    [21] Zhou B K, Gao Y Z, Chen T R et al[M]. The principle of laser, 72-83(2014).

    [22] Cao K, Liang C Q, Guo R M et al[J]. Study on temperature control for ring-down cavity Acta Metrologica Sinica, 2018, 431-435.

    [23] Su W, Guo R M, Xing S X et al[J]. Study on temperature control of optical cavity with high stability and uniformity Measurement Technique, 2018, 10-12, 42.

    [24] Wang D, Hu R Z, Xie P H et al. Fast and accurate extraction of ring-down time in cavity ring-down spectroscopy[J]. Spectroscopy and Spectral Analysis, 34, 2845-2850(2014).

    Dong Hewei, Guo Ruimin, Cui Wenchao, Li Dong. Cavity Ring-Down Spectroscopy Based on Folded Cavity[J]. Chinese Journal of Lasers, 2020, 47(3): 311001
    Download Citation