• Journal of Infrared and Millimeter Waves
  • Vol. 21, Issue 3, 218 (2002)
[in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article
    [in Chinese], [in Chinese], [in Chinese]. DEVELOPMENT OF A MILLISECOND PULSE-HEATING APPARATUS WITH A MULTI-WAVELENGTH PYROMETER AND AN INTEGRATING REFLECTOMETER FOR THERMOPHYSICAL PROPERTIES MEASUREMENT[J]. Journal of Infrared and Millimeter Waves, 2002, 21(3): 218 Copy Citation Text show less
    References

    [2] DAI Jing-Min, FAN Yi, CHU Zai-Xiang. Development of a millisecond pulse-heating apparatus in China. International Journal of Thermophysics,to be published,2002

    [3] Cezairliyan A. Advances in measurements of thermophysical propertie by dynamic techniques. High Temp. High Press., 1979,11:9-27

    [4] Cezairliyan A. A millisecond-resolution pulse heating system for specific-heat measurements at high temperatures. In: Maglic K D, Cezairliyan A, Peletskii V E(eds). Compendium of Thermophysical Property Measurement Methods. Vol.1, New York:Plenum,1984,643-668

    [5] Righini F, Bussolino G C, Spisiak J. Pulse calorimetry at high temperatures. Thermochimica Acta, 2000,347;93-102

    [6] Cezairliyan A, Krishnan S, McClure J L. Simultaneous measurements of normal spectral emissivity by spectral radiometry and laser polarimetry at high temperatures in millisecond-resolution pulse-heating experiments: application to molybdenum and tungsten. Int. J. Thermophysics, 1996,17:1455-1473

    [7] Righini F, Spisiak J, Bussolino G C. Normal spectral emissivity of niobium(at 900nm) by a pulse-heating reflectometric technique. Int. J. Thermophysics, 1999, 20:1095-1106

    [8] Cezairliyan A, Krishnan S, Basak D, et al. Application of laser polarimetry to the measurement of the specific heat capacity of molybdenum in the range 2000 to 2800K by a pulse-heating technique. Int.J.Thermophysics, 1998, 19:1267-1276

    [9] Righini F, Spisiak J, Bussolino G C, et al. Thermophysical properties by a pulse-heating reflectometric technique: niobium, 1100 to 2700K. Int.J.Thermophysics, 1999,20:1107-1116

    [11] Ruffino G, CHU Zai-Xiang, KANG Song-Gao, et al. Wavelength pyrometer with photodiode array. Temp., its Meas. and Contr. in Sci. and Industry, 1991,6:807-811

    [in Chinese], [in Chinese], [in Chinese]. DEVELOPMENT OF A MILLISECOND PULSE-HEATING APPARATUS WITH A MULTI-WAVELENGTH PYROMETER AND AN INTEGRATING REFLECTOMETER FOR THERMOPHYSICAL PROPERTIES MEASUREMENT[J]. Journal of Infrared and Millimeter Waves, 2002, 21(3): 218
    Download Citation