    Abstract

    In this paper, Orthographic dual- object beam holographic interferometry limited-view CT technique is suggested. Using this technique, object field informations simultaneously is obtaniced from orthogonal dual-directions. Temperature field of a cross section of thermal air flow for burner is reconstructed by circulating algebraic iterative relax mwthod with satisfied reconstructed accuracy. Reconstructed temperatures is identical with the measured temperatures using four thermocouples.
    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Orthographic Dual-Object Beam Holography Limited-View CT Technique Applied to Reconstruct Temperature Field for Burner[J]. Acta Optica Sinica, 1995, 15(9): 1240