• Acta Optica Sinica
  • Vol. 33, Issue 6, 611001 (2013)
Wang Baosheng1、*, Gao Shumei1, Wang Jicheng1, Zhu Jianqiang2, and Liu Cheng1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201333.0611001 Cite this Article Set citation alerts
    Wang Baosheng, Gao Shumei, Wang Jicheng, Zhu Jianqiang, Liu Cheng. Influence of Charge Coupled Device Saturation on PIE Imaging[J]. Acta Optica Sinica, 2013, 33(6): 611001 Copy Citation Text show less
    References

    [1] B. Abbey, K. A. Nugent, G. L. Willianms et al.. Keyhole coherent diffractive imaging [J]. Nature Physics, 2008, 4(5): 394~398

    [2] J. C. H. Spence, U. Weierstall, M. Howells et al.. Coherence and sampling requirements for diffractive imaging [J]. Ultramicroscopy, 2004, 101(2-4): 149~152

    [3] P. Thibault, M. Dierolf, A. Menzel et al.. High-resolution scanning X-ray diffraction microscopy [J]. Science, 2008, 321(5887): 379~382

    [4] O. El Gawhary, N. Kumar, S. F. Pereira et al.. Performance analysis of coherent optical scatterometry [J]. Appl. Phys. B, 2011, 105(4): 755~781

    [5] U. Weierstall, Q. Chen, J. C. H Spence et al.. Image reconstruction from electron and X-ray diffraction patterns using iterative algorithms experiment and simulation [J]. Ultramicroscopy, 2002, 90(2-3): 171~195

    [6] J. R. Fienup. Phase retrival alogorithms: a comparison [J]. Appl. Opt., 1982, 21(15): 2758~2769

    [7] J. M. Rodenburg. Ptychography and related diffractive imaging methods [J]. Advances in Imaging Electron Phys., 2008, 150: 87~184

    [8] J. M. Rodenburg. A simple model of holography and some enhanced resolution methods in electron microscopy [J]. Ultramicroscopy, 2001, 87(3): 105~121

    [9] C. Liu, T. Walther, J. M. Rodenburg. Influence of thick crystal effects on ptychographic image reconstruction moveable illumination [J]. Ultramicroscopy, 2009, 109(10): 1263~1275

    [10] H. M. L. Faulkner, J. M. Rodenburg. Movable aperture lenseless tranmmission microscopy: a novel phase retrieval algorithm [J]. Phys. Rev. Lett., 93(2): 023903

    [11] J. M. Rodenburg, A. C. Hurst, A. G. Cullis. Transmission microscopy without lenses for objects of unlimited size [J]. Ultramicroscopy, 2007, 107(2-3): 227~231

    [12] H. M. L. Faulkner, J. M. Rodenburg. Error tolerance of an interative phase retriveval for moveable illumination [J]. Ultramicroscopy, 2005, 103(2): 153~164

    [13] F. Hüe, J. M. Rodenburg, A. M. Maiden et al.. Wavefront phase retrieval in transmission electron microscopy via ptychography [J]. Phys. Rev. B, 2010, 82(12): 121415

    [14] P. Thibault, M. Dierrolf, O. Bunk et al.. Probe retrieval in ptychographic coherent diffractive imaging [J]. Ultramicroscopy, 2009, 109(4): 338~343

    [15] Pan Xingchen, Lin Qiang, Liu Cheng et al.. Influence of the partial coherence to the PIE imaging method [J]. Scientia Sinica Physica, Mechanica & Astronomica, 2012, 42(9): 889~898

    CLP Journals

    [1] Pan An, Zhang Yan, Zhao Tianyu, Wang Zhaojun, Dan Dan, Shi Yishi, Yao Baoli. Quantitative Phase Microscopy Imaging Based on Ptychography[J]. Laser & Optoelectronics Progress, 2017, 54(4): 40001

    [2] He Jing, Liu Cheng, Gao Shumei, Wang Jicheng, Wang Yueke, Zhu Jianqiang. Microscopic PIE Imaging With Theory of Compressive Sensing[J]. Acta Optica Sinica, 2014, 34(5): 511008

    [3] Zuo Chao, Chen Qian, Sun Jiasong, Anand Asundi. Non-Interferometric Phase Retrieval and Quantitative Phase Microscopy Based on Transport of Intensity Equation: A Review[J]. Chinese Journal of Lasers, 2016, 43(6): 609002

    [4] Chen Wen, Jiang Zhilong, Liu Cheng, Zhu Jianqiang. Depth Resolved Imaging by 3PIE with Dual-Beam Illumination[J]. Collection Of theses on high power laser and plasma physics, 2016, 14(1): 811002

    [5] Zheng Chen, He Xiaoliang, Liu Cheng, Wang Yueke, Wang Jicheng, Zhu Jianqiang. A Study on the Influence of the Axial Distance Error to the Image Quality of the Ptychographic Iterative Engine[J]. Acta Optica Sinica, 2014, 34(10): 1011003

    Wang Baosheng, Gao Shumei, Wang Jicheng, Zhu Jianqiang, Liu Cheng. Influence of Charge Coupled Device Saturation on PIE Imaging[J]. Acta Optica Sinica, 2013, 33(6): 611001
    Download Citation