• Acta Photonica Sinica
  • Vol. 38, Issue 8, 2131 (2009)
ZHANG Yan-bo*, TANG Shao-jie, and MOU Xuan-qin
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article
    ZHANG Yan-bo, TANG Shao-jie, MOU Xuan-qin. Improvement of Bi-polynomial Method for Beam Hardening Correction Based on Consistency of CT Data[J]. Acta Photonica Sinica, 2009, 38(8): 2131 Copy Citation Text show less

    Abstract

    Due to all kinds of correction algorithms have little effects on streak artifact at present,the reason of streak artifact is analyzed.Therefore,considering that the influence of soft tissue caused by the X-rays which penetrate through different bone thicknesses are different,the soft tissue correction polynomial in Bi-Polynomial correction method is improved based on H-L consistency condition.Forbild head phantom simulation results show that the improved algorithm can get better correction effect on both cupping artifact and streak artifact.
    ZHANG Yan-bo, TANG Shao-jie, MOU Xuan-qin. Improvement of Bi-polynomial Method for Beam Hardening Correction Based on Consistency of CT Data[J]. Acta Photonica Sinica, 2009, 38(8): 2131
    Download Citation