    Change between image and camera coordinate systems caused by camera shake
    Fig. 1. Change between image and camera coordinate systems caused by camera shake
    Displacements of target point. (a) Applied displacements; (b) displacements before and after DIC-based correction
    Fig. 2. Displacements of target point. (a) Applied displacements; (b) displacements before and after DIC-based correction
    Correction error of affine transformation model versus working distance
    Fig. 3. Correction error of affine transformation model versus working distance
    Experimental setup. (a) Schematic; (b) physical map
    Fig. 4. Experimental setup. (a) Schematic; (b) physical map
    Displacements before and after correction for two test experiments. (a) Displacements in x direction; (b) displacements in y direction
    Fig. 5. Displacements before and after correction for two test experiments. (a) Displacements in x direction; (b) displacements in y direction
    Absolute value of errorT1T2
    x displacementy displacementx displacementy displacement
    Maximum0.1010.1120.1570.100
    Mean value0.0600.0300.0570.038
    Standard deviation0.0290.0280.0390.028