• Photonic Sensors
  • Vol. 6, Issue 4, 324 (2016)
Susana SILVA1, Regina MAGALHAES1, Rosa Ana PEREZ-HERRERA2, Manuel LOPEZ-AMO2, M. B. MARQUES1, and O. FRAZAO1
Author Affiliations
  • 1INESC TEC, Rua do Campo Alegre 687, 4169-007 Porto, Portugal and Dept. de Física e Astronomia da Faculdade de Ciencias da Universidade do Porto, Rua do Campo Alegre 687, 4169-007 Porto, Portugal
  • 2Public University of Navarra, Dept. of Electric and Electronic Engineering, Campus de Arrosadía, Pamplona, Spain.
  • show less
    DOI: 10.1007/s13320-016-0309-9 Cite this Article
    Susana SILVA, Regina MAGALHAES, Rosa Ana PEREZ-HERRERA, Manuel LOPEZ-AMO, M. B. MARQUES, O. FRAZAO. Fiber Cavity Ring Down and Gain Amplification Effect[J]. Photonic Sensors, 2016, 6(4): 324 Copy Citation Text show less
    References

    [1] J. M. Herbelin, J. A. McKay, M. A. Kwok, R. H. Uenten, D. S. Urevig, D. J. Spencer, et al., “Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method,” Applied Optics, 1980, 19(1): 144–147.

    [2] D. Z. Anderson, J. C. Frisch, and C. S. Masser, “Mirror reflectometer based on optical cavity decay time,” Applied Optics, 1984, 23(8): 1238–1245.

    [3] A. O’Keefe and D. A. G. Deacon, “Cavity-ring-down optical spectrometer for absorption measurements using pulsed laser sources,” Review of Scientific Instruments, 1988, 59(12): 2544–2551.

    [4] G. Berden, R. Peeters, and G. Meijer, “Cavity ring-down spectroscopy: experimental schemes and applications,” International Reviews in Physical Chemistry, 2000, 19(4): 565–607.

    [5] G. Stewart, K. Atherton, H. Yu, and B. Culshaw, “An investigation of an optical fiber amplifier loop for intra-cavity and ring-down cavity loss measurements,” Measurement Science and Technology, 2001, 12(12): 843–849.

    [6] N. Ni, C. C. Chan, X. Y. Dong, J. Sun, and P. Shum, “Cavity ring-down long period fiber grating strain sensor,” Measurement Science Technology, 2007, 18(10): 3135–3138.

    [7] C. Wang and S. T. Scherrer, “Fiber ring-down pressure sensors,” Optics Letters, 2004, 29(4): 352–354.

    [8] C. Wang, “Fiber ringdown temperature sensor,” Optical Engineering, 2005, 44(3): 030503.

    [9] W. C. Wong, W. Zhou, C. C. Chan, X. Dong, and K. C. Leong, “Cavity ring-down refractive index sensor using photonic crystal fiber interferometer,” Sensors and Actuators B Chemical, 2013, 161(1): 108–113.

    [10] C. M. Rushworth, D. James, J. W. L. Lee, and C. Vallance, “Top notch design for fiber-loop cavity ring-down spectroscopy,” Analytical Chemistry, 2011, 83(22): 8492–8500.

    [11] G. Stewart, K. Atherton, and B. Culshaw, “Cavity-enhanced spectroscopy in fiber cavities,” Optics Letters, 2004, 29(5): 442–444.

    [12] B. Vizoso, C. Vfizquez, R. Civera, M. Lopez-Amo, and M. A. Muriel, “Amplified fiber-optic recirculating delay lines,” Journal of Lightwave Technology, 1994, 12(2): 294–305.

    [13] M. Fabian, E. Lewis, T. Newe, and S. Lochmann, “Optical fiber cavity for ring-down experiments with low coupling losses,” Measurement Science and Technology, 2010, 21(9): 094034.

    [14] D. J. Passos, S. O. Silva, J. R. A. Fernandes, M. B. Marques, and O. FrazAo, “Fiber cavity ring-down monitoring with an optical time-domain reflectometer,” Photonic Sensors, 2014, 4(4): 295–299.

    Susana SILVA, Regina MAGALHAES, Rosa Ana PEREZ-HERRERA, Manuel LOPEZ-AMO, M. B. MARQUES, O. FRAZAO. Fiber Cavity Ring Down and Gain Amplification Effect[J]. Photonic Sensors, 2016, 6(4): 324
    Download Citation