    Liangzong Zhang, Tao Yang, Yun Wu, Tao Tang. Image measurement-based two-stage control of Stewart platform[J]. Opto-Electronic Engineering, 2022, 49(8): 220019 Copy Citation Text show less
    System schematic
    Fig. 1. System schematic
    Traditional two-stage control system
    Fig. 2. Traditional two-stage control system
    Improved two-stage control system
    Fig. 3. Improved two-stage control system
    Closed loop system of the coarse stage
    Fig. 4. Closed loop system of the coarse stage
    Frequency response curve of the Stewart platform
    Fig. 5. Frequency response curve of the Stewart platform
    Closed loop system of the fine stage
    Fig. 6. Closed loop system of the fine stage
    Integral controller and pi-pi control error suppression curve simulation diagram
    Fig. 7. Integral controller and pi-pi control error suppression curve simulation diagram
    Experimental diagram of the two-stage system
    Fig. 8. Experimental diagram of the two-stage system
    The error suppression curve of the PI and PI-PI controller is compared
    Fig. 9. The error suppression curve of the PI and PI-PI controller is compared
    The two-stage system experiment. (a) f=0.05 Hz; (b) f=0.80 Hz
    Fig. 10. The two-stage system experiment. (a) f=0.05 Hz; (b) f=0.80 Hz
    The process of unloading quantization in two-stage control
    Fig. 11. The process of unloading quantization in two-stage control
    The tracking error of single-order structure and two-step structure is compared. (a) 0.01 Hz;(b) 0.02 Hz;(c) 0.05 Hz
    Fig. 12. The tracking error of single-order structure and two-step structure is compared. (a) 0.01 Hz;(b) 0.02 Hz;(c) 0.05 Hz
    Frequency/HzSingle-order structure/(′′)Double-order structure/(′′)
    0.0126.160053.172951
    0.0249.770285.876996
    0.05129.200314.38101
    Table 1. RMS comparison of tracking errors between single-order structure and double-order structure at three frequencies
    Liangzong Zhang, Tao Yang, Yun Wu, Tao Tang. Image measurement-based two-stage control of Stewart platform[J]. Opto-Electronic Engineering, 2022, 49(8): 220019