• Acta Optica Sinica
  • Vol. 30, Issue 12, 3508 (2010)
Song Zongxi1、2、*, Zhao Baochang1, Gao Wei1, Yang Jianfeng1, and Ruan Ping1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos20103012.3508 Cite this Article Set citation alerts
    Song Zongxi, Zhao Baochang, Gao Wei, Yang Jianfeng, Ruan Ping. Focal Plane Design of Chang′e-1 Satellite CCD Stereo-Camera and Laboratory Radiation Calibration[J]. Acta Optica Sinica, 2010, 30(12): 3508 Copy Citation Text show less
    References

    [1] Zhao Baochang, Yang Jianfeng, He Yinghong et al.. Lunar exploration optics[J]. Acta Photonica Sinica, 2009, 38(3): 461~467

    [2] J. Bell, J. Joseph, J. Sohl-Dickstein. MER/Pancam data processing user′s guide[DB/OL]. http://pds-geosciences.wustl.edu/mer/mer2-m-pancam-2-edr-sci-v1/mer2pc_0xxx/document/pancam_users_guide.pdf

    [3] Y. G. Shkuratov, M. A. Kreslavsky, A. A. Ovcharenko et al.. Opposition effect from Clementine data and mechanisms of backscatter[J]. Icarus, 1999, 144(1): 132~155

    [4] S. Nozette, P. Ruston, L. P. Pleasance et al.. The clementine mission to the moon: scientific overview[J]. Science, 1994, 266(5192): 1835~1839

    [5] Chon Trung Hua. Ultraviolet diffuse reflectance spectroscopy for lunar, meteoritic, and terrestrial samples[C]. Proc. Lunar Sci. Conf. 1976. 2605~2622

    [6] P. Lucey, R. L. Korotev, J. J. Giuis et al.. Understanding the lunar surface and space-moon interactions[J]. Rev. Mineral. Geochem., 2006, 60: 83~219

    [7] S. Tompkins, C. M. Pieters. Mineralogy of the lunar crust: results from Clementine[J]. Meterori. Planet. Sci., 1999, 34(1): 25~41

    [8] J. M. Sunshine, C. M. Pieters. Determining the composition of olivine from reflectance spectroscopy[J]. J. Geophys. Res., 1998, 102(E6): 13675~13688

    [9] M. A. Wieczorek, R. J. Philips. The structure and compensation of the lunar hightland crust[J]. J. Geophys. Res., 1997, 102(E5): 10933~10943

    [10] A. S. Mcewen, M. S. Robinson, E. M. Eliason et al.. Clementine observations of the Aristarchus region of the Moon[J]. Science, 1994, 266(5192): 1858~1862

    [11] C. M. Pieters. The moon as a spectral calibration standard enabled by lunar samples: the clementine example[C]. Workshop on New Views of the Moon 2: Understanding the Moon Through the Integration of Diverse Datasets, 1999

    [12] J. A. Mendenhall, D. E. Lencioni, A. C. Parker. Radiometric calibration of the EO-1 advanced land imager[C]. SPIE, 1999, 3750: 117~131

    [13] Y. G. Shkuratov, V. G. Kaidash, M. A. Kroslarsky et al.. Absolute calibration of the clementine UVVIS data: comparison with ground-based observation of the moon[J]. Sol. Sys. Res., 2001, 35(1): 29~34

    [14] J. Campos. Radiometric calibration of charge-coupled-device video cameras[J]. Metrologia, 2000, 37(5): 459~464

    [15] A. R. Eisenman, C. C. Liebe, R. Perez. The mars exploration rover suncam[EB/OL]. http://trs-new.jpl.nasa.gov/dspace/bitstream/2014/13331/1/01-2119.pdf

    [16] J. N. Maki, J. F. Bell, K. E. Horkonhalf et al.. Mars exploration rover engineering cameras[J]. J. Geophys. Res, 2003, 108(E12): 1~24

    [17] D. T. Janzen, A. L. Fredeen, R. D. Wheate. Radiometric correction techniques and accuracy assessment for Landsat TM data in remote forested regions[J]. Can. J. Remote Sens., 2006, 32(5): 330~340

    [18] M. Robinson, M. Riner. Advances in lunar science from the Clementine mission: a decadal perspective Mark[J]. J. Earth Sys. Sci., 2005, 114(6): 669~686

    [19] P. N. Slater, S. F. Biggar, K. J. Thome et al.. Vicarious radiometric calibrations of EOS sensors[J]. J. Atmos. Ocean. Technol, 1996, 13(2): 349~359

    [20] Feng Yu, Zheng Xiaobin, Zhang Wei et al.. Optical radiometric calibration based on correlated photons[J]. Acta Optica Sinica, 2007, 27(3): 457~460

    CLP Journals

    [1] Zhang Yanna, Zheng Xiaobing, Li Jianjun, Zhang Wei. Research on System Level Calibration Method of Multi-Band Filter Radiometer[J]. Acta Optica Sinica, 2013, 33(8): 812004

    [2] Chang Fei, Liu Jin, Xie Xingquan, Zhang Xuedong, Zhou Jing, Guo Zhongping. Auto-Testing Technology for Main Factors of Reliability of Monitoring CCD Camera[J]. Chinese Journal of Lasers, 2012, 39(s2): 208008

    [3] Cheng Xuan, Zhao Huijie. Dark-Current Calculation Method of Area CCD Based on Bad Pixels Detection in the Scene[J]. Acta Optica Sinica, 2012, 32(4): 404002

    [4] Kong Ningning, Li Chao, Xia Mingliang, Qi Yue, Li Dayu, Xuan Li. Research on Flat Field Correction Method in Adaptive Optics Retinal Imaging System[J]. Acta Optica Sinica, 2011, 31(12): 1211001

    [5] Xie Xufen, Zhang Wei, Zhi Xiyang, Zhao Ming, Wang Hongyuan. Scene-Based Assessment Method for Nonuniformity of Infrared Focal Plane Array[J]. Acta Optica Sinica, 2012, 32(6): 604001

    [6] Zheng Liangliang, Zhang Guixiang, He Xiaojun, Qu Hongsong, Jin Guang. Research on Response Model of TDI CCD Image System[J]. Acta Optica Sinica, 2014, 34(11): 1104001

    [7] Xu Yanfang, Liu Haoxue, Huang Min, Song Yuehong. Study on a Correlation Model for Text Perceptual Distinctness[J]. Acta Optica Sinica, 2012, 32(12): 1233001

    Song Zongxi, Zhao Baochang, Gao Wei, Yang Jianfeng, Ruan Ping. Focal Plane Design of Chang′e-1 Satellite CCD Stereo-Camera and Laboratory Radiation Calibration[J]. Acta Optica Sinica, 2010, 30(12): 3508