• Opto-Electronic Engineering
  • Vol. 41, Issue 12, 28 (2014)
HU Zhixiong1、*, LIU Wenli1, HONG Baoyu1, HAO Bingtao1, WANG Lele2, and LI Jiao1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2014.12.006 Cite this Article
    HU Zhixiong, LIU Wenli, HONG Baoyu, HAO Bingtao, WANG Lele, LI Jiao. A Physical Model Eye with 3D Resolution Test Targets for Optical Coherence Tomography[J]. Opto-Electronic Engineering, 2014, 41(12): 28 Copy Citation Text show less
    References

    [1] Huang David, Swanson Eric A, Lin Charles P, et al. Optical coherence tomography[J]. Science(S0036-8075), 1991, 254(5035): 1178-1181.

    [2] CHEN Wei, XUE Ping, YUAN Tao, et al. Medical Dianosis Research Using Optical Coherence Tomography[J]. Acta Photonica Sinica, 1999, 28(11): 970-973.

    [3] XUE Ping, CHEN Zeming. New Technique of Cross-sectioning Imaging Optical Coherence Tomography[J]. Physics and Engineering, 2001, 11(3): 39-43.

    [4] Tomlins P H, Wang R. Theory, developments and applications of optical coherence tomography[J]. Journal of Physics D: Applied Physics(S0022-3727), 2005, 38(15): 2519.

    [5] MENG Zhuo, YAO X Steve, YAO Hui, et al. Detecting Early Artificial Caries by Using Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2010, 37(11): 2709-2713.

    [6] Marschall Sebastial, Sander Birgit, Mogensen Mette, et al. Optical coherence tomography—current technology and applications in clinical and biomedical research[J]. Analytical and Bioanalytical Chemistry(S1618-2642), 2011, 400(9): 2699-2720.

    [7] SHI Guohua, DING Zhihua, DAI Yun, et al. Ophthamic Imaging by Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2008, 35(9): 1429-1431.

    [8] SHI Guohua, WANG Fei, LI Xiqi, et al. Morphometric Measurement of Schlemm’s Canal Using Anterior Segment Swept Source Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2013, 50(8): 136-141.

    [9] Tomlins Peter H, Ferguson Robert A, Hart Christian, et al. Point-Spread Function Phantoms for Optical Coherence Tomography [R]. National Physical Labratorary report, 2009.

    [10] Agrawal Anant, Pfefer T Joshua, Gilani Naureen, et al. Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom[J]. Optics Letters(S0146-9592), 2010, 35(13): 2269-2271.

    [11] Chang Robert C, Johnson Peter, Stafford Christopher M, et al. Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials[J]. Biomedical Optics Express(S2156-7085), 2012, 3(6): 1326-1339.

    [12] Avanaki Mohammad R N, Podoleanu Adrian Gh, Price Mark C, et al. Two applications of solid phantoms in performance assessment of optical coherence tomography systems[J]. Applied Optics(S1559-128X), 2013, 52(29): 7054-7061.

    [14] De Bruin Daniel M, Bremmer Rolf H, Kodach Vitli M, et al. Optical phantoms of varying geometry based on thin building blocks with controlled optical properties[J]. Journal of Biomedical Optics(S1083-3668), 2010, 15(2): 025001-025001-10.

    [15] Baxi Jigesh, Calhoun William, Sepah Yasir Jamal, et al. Retina-simulating phantom for optical coherence tomography[J]. Journal of Biomedical Optics(S1083-3668), 2014, 19(2): 021106-021106.

    [16] Tomlins Peter H, Smith Graham N, Woolliams Peter D, et al. Femtosecond laser micro-inscription of optical coherence tomography resolution test artifacts[J]. Biomedical Optics Express(S2156-7085), 2011, 2(5): 1319-1327.

    [17] Curatolo Andrea, Kennedy Brendan F, Sampson David D. Structured three-dimensional optical phantom for optical coherence tomography[J]. Optics Express(S1094-4087), 2011, 19(20): 19480-19485.

    [18] GU Ruoyu, Lurie Kristen L, Pipes Meagan, et al. Variable-sized bar targets for characterizing three-dimensional resolution in OCT[J]. Biomedical Optics Express(S2156-7085), 2012, 3(9): 2317-2325.

    CLP Journals

    [1] Wang Ling, Tu Pei, Shi Ran, Xu Ming′en. Quantitative Evaluation of Three-Dimensional Bio-Printed Hydrogel Scaffolds by Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2015, 42(8): 804003

    [2] Zhou Haibin, Lei Xinzhuo, Zhou Wang, Xu Feng. Overall Design of Miniature Spectrometer Based on Android[J]. Laser & Optoelectronics Progress, 2016, 53(6): 63001

    [3] Lü Wei, ZHAI Qingwei, CHU Jinghui, LI Zhe. Automated Detection of Diabetic Retinopathy Exudates in Color Fundus Images[J]. Opto-Electronic Engineering, 2016, 43(12): 183

    HU Zhixiong, LIU Wenli, HONG Baoyu, HAO Bingtao, WANG Lele, LI Jiao. A Physical Model Eye with 3D Resolution Test Targets for Optical Coherence Tomography[J]. Opto-Electronic Engineering, 2014, 41(12): 28