• Laser & Optoelectronics Progress
  • Vol. 50, Issue 8, 80008 (2013)
Ma Jingui1、*, Wang Yongzhi1, Yuan Peng2, Wang Jing2, Zhu Heyuan1, and Qian Liejia1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/lop50.080008 Cite this Article Set citation alerts
    Ma Jingui, Wang Yongzhi, Yuan Peng, Wang Jing, Zhu Heyuan, Qian Liejia. Single-Shot Pulse-Contrast Measurement for High-Intensity Lasers[J]. Laser & Optoelectronics Progress, 2013, 50(8): 80008 Copy Citation Text show less
    References

    [1] D Umstadter. Review of physics and application of relativistic plasma driven by ultra-intense lasers[J]. Phys Plasmas, 2004, 8(5):1774-1785.

    [2] N Forget, A Cotel, E Brambrink, et al.. Pump-noise transfer in optical parametric chirped-pulse amplification[J]. Opt Lett, 2005, 30(21): 2921-2923.

    [3] C Dorrer. Analysis of pump-induced temporal contrast degradation in optical parametric chirped-pulse amplification[J]. J Opt Soc Am B, 2007, 24(12): 3048-3057.

    [4] N V Didenko, A V Konyashchenko, A P Lutsenko, et al.. Contrast degradation in a chirped-pulse amplifier due to generation of prepulses by postpulses[J]. Opt Express, 2008, 16(5): 3178-3190.

    [5] D N Schimpf, E Seise, J Limpert, et al.. The impact of spectral modulations on the contrast of pulses of nonlinear chirped-pulse amplification systems[J]. Opt Express, 2008, 16(14): 10664-10674.

    [6] H Kiriyama, T Shimomura, H Sasao, et al.. Temporal contrast enhancement of petawatt-class laser pulses[J]. Opt Lett, 2006, 37(16): 3363-3365.

    [7] A Jullien, O Albert, F Burgy, et al.. 10-10 temporal contrast for femtosecond ultraintense lasers by cross-polarized wave generation[J]. Opt Lett, 2005, 30(8): 920-922.

    [8] Y Huang, C Zhang, Y Xu, et al.. Ultrashort pulse temporal contrast enhancement based on noncollinear optical-parametric amplification[J]. Opt Lett, 2011, 36(6): 781-783.

    [9] P Yuan, G Xie, D Zhang, et al.. High-contrast near-IR short pulses generated by a mid-IR optical parametric chirped-pulse amplifier with frequency doubling[J]. Opt Lett, 2010, 35(11): 1878-1880.

    [10] J Ma, P Yuan, Y Wang, et al.. Numerical study on pulse contrast enhancement in a short-pulse-pumped optical parametric amplifier[J]. Opt Commun, 2012, 285(21-22): 4531-4536

    [11] K-H Hong, B Hou, J A Nees, et al.. Generation and measurement of >108 intensity contrast ratio in a relativistic kHz chirped-pulse amplifier laser[J]. Appl Phys B, 2005, 81(4): 447-457.

    [12] E J Divall, I N Ross. High dynamic range contrast measurements by use of an optical parametric amplifier correlator[J]. Opt Lett, 2004, 29(19): 2273-2275.

    [13] J Collier, C Hernandez-Gomez, R Allott, et al.. A single-shot third-order autocorrelator for pulse contrast and pulse shape measurements[J]. Laser Part Beams, 2001, 19(2): 231-235.

    [14] G Priebe, K A Janulewicz, V I Redkorechev, et al.. Pulse shape measurement by a non-collinear third-order correlation technique[J]. Opt Commun, 2006, 259(2): 848-851.

    [15] I Jovanovic, C Brown, C Haefner, et al.. High-dynamic-range, 200-ps window, single-shot cross-correlator for ultrahigh intensity laser characterization[C]. CLEO/QELS, 2007. JThD137.

    [16] R C Shah, R P Johnson, T Shimada, et al.. Large temporal window contrast measurement using optical parametric amplification and low-sensitivity detectors[J]. Eur Phys J D, 2009, 55(2): 305-309.

    [17] C Dorrer, J Bromage, J D Zuegel. High-dynamic-range single-shot cross-correlator based on an optical pulse replicator[J]. Opt Express, 2008, 16(18): 13534-13544.

    [18] J Ma, P Yuan, Y Wang, et al.. Single-shot cross-correlator using a long-wavelength sampling pulse[J]. Opt Lett, 2011, 36(6): 978-980.

    [19] J Ma, Y Wang, P Yuan, et al.. Single-shot pulse-contrast measurement based on high-order quasi-phase-matching cross-correlation[J]. Opt Lett, 2012, 37(21): 4486-4488.

    [20] D Zhang, L Qian, P Yuan, et al.. Fiber-array-based detection scheme for single-shot pulse contrast characterization[J]. Opt Lett, 2008, 33(17): 1969-1971.

    [21] Y Wang, P Yuan, J Ma, et al.. Scattering noise and measurement artifacts in a single-shot cross-correlator and their suppression[J]. Appl Phys B, 2013, 111(3): 501-508.

    [22] Wang Yongzhi, Ouyang Xiaoping, Ma Jingui, et al.. First application of single-shot cross-correlator for characterizing Ndglass petawatt pulses[J]. Chin Phys Lett, 2013, 30(2): 024201

    CLP Journals

    [1] Tao Shixing, Deng Xiangyang, Li Jianzhong, Wang Jing, Peng Qixian. Real-Time Measurement of Light Beat-Frequency Signal with Bandwidth of 56.978 GHz[J]. Acta Optica Sinica, 2017, 37(3): 306004

    [2] Bao Wenxia, Zhang Nan, Kong Mengqing, Zhu Xiaonong. Measurement of Ultrashort Pulse Laser with Scanning Third Order Correlation Technique[J]. Chinese Journal of Lasers, 2015, 42(7): 708009

    [3] Shi Shuaixu, Yang Qingwei, Ouyang Xiaoping, Xia Suqiu, Zhu Jianqiang. Measurement Technique of Signal Noise Ratio Based on Resonator Oscillation for Femtosecond Single-Shot Pulse[J]. Collection Of theses on high power laser and plasma physics, 2016, 14(1): 904001

    Ma Jingui, Wang Yongzhi, Yuan Peng, Wang Jing, Zhu Heyuan, Qian Liejia. Single-Shot Pulse-Contrast Measurement for High-Intensity Lasers[J]. Laser & Optoelectronics Progress, 2013, 50(8): 80008
    Download Citation