• Acta Photonica Sinica
  • Vol. 48, Issue 12, 1248006 (2019)
Chang-ming LIU1、1、2、2, Xue-shun SHI1、1、2、2、*, Peng-ju ZHANG1、1、2、2, Xin-gang ZHUANG1、1、2、2, and Hong-bo LIU1、1、2、2
Author Affiliations
  • 1The 41 st Research Institute of China Electronic Science and Technology Group, Qingdao, Shandong 266555, China
  • 2National Opto-Electronic Primary Metrology Laboratory, Qingdao, Shandong 266555, China
  • show less
    DOI: 10.3788/gzxb20194812.1248006 Cite this Article
    Chang-ming LIU, Xue-shun SHI, Peng-ju ZHANG, Xin-gang ZHUANG, Hong-bo LIU. Detection Efficiency Measurement of Silicon Single-photon Avalanche Detector Traceable Using Standard Detector[J]. Acta Photonica Sinica, 2019, 48(12): 1248006 Copy Citation Text show less
    References

    [1] G BRIDA, S CASTELLETTO, I P DEGIOVANNI. Quantum efficiency and dead time of single-photon counting photodiodes:a comparison between two measurement techniques. Metrologia, 37, 625-628(2000).

    [2] M WARE, A MIGDALL. Single-photon detector characterization using correlated photons:the march from feasibility to metrology. Journal of Modern Optics, 51, 1549-1557(2004).

    [3] A GHAZI-BELLOUATI, A RAZET, M E HIMBERT. Radiometric reference for weak radiations:comparison of methods. Metrologia, 42, 271-277(2005).

    [4] M WARE, A MIGDALL, J C BIENFANG. Calibrating photon-counting detectors to high accuracy:backgroound and deadtime issues. Journal of Modern Optics, 54, 361-372(2007).

    [5] S V POLYAKOV, A L MIGDALL. High accuracyverification of a correlated-photon-based method for determining photon-counting detection efficiency. Optics Express, 15, 1390-1407(2007).

    [6] POLYAKOV S V, MIGDALL A. High accuracycalibration of photoncounting detects "on dem"[C]. SPIE, 2007, 6583: 65830A.

    [7] J Y CHEUNG, C J CHUNNILALL, G PORROVECCHIO. Low optical poewr reference detector omplemented in the validation of. Optics Express, 19, 20347-20363(2011).

    [8] M LOPEZ, H HOFER, S KUCK. Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique. Journal of Modern Optics, 62, 1732-1738(2015).

    [9] K DHOSKA, H HOFER, B RODIEK. Improvement of the detection efficiency calibration and homogeneity measurement of Si-SPAD detectors. Springerplus, 5, 2065(2016).

    [12] S COVA, A LACAITA, G RIPAMONTI. Trapping phenomena in avalanche photodiodes on nanosecond scale. IEEE Electron Device Letters, 12, 685-687(1991).

    [13] L CAMPBELL. After measurement and correction. Review of Scientific Instruments, 63, 5794-5798(1992).

    [15] B IN-HO, P SEONGCHONG, H KEE-SUK. Detection efficiency measurement of single photon avalanche photodiodes by using a focused monochromatic beam tunable from 250 nm to 1000 nm. Metrologia, 56, 035003(2019).

    [16] L TOMMSAO, K BORIS, S BRUNO. Absolute calibration of fiber-coupled single-photon detector. Optics Express, 22, 18078-18092(2014).

    [18] F ALEJADRO, C JOAQUIN, P ALICIA. New model for the internal quantum efficiency of photodiodes based on photocurrent analysis. Applied Optics, 44, 208-216(2005).

    [19] T R GENTILE, S W BROWN, K R LYKKE. Internal quantum efficiency modeling of silicon photodiodes. Applied Optics, 49, 1859-1864(2010).

    [20] Excelitas Technologies. Excelitas SPCMAQRH family datasheet[NOL]. (201812)[20190815]. https:www.excelitas.comproductspcmaqrh.

    Chang-ming LIU, Xue-shun SHI, Peng-ju ZHANG, Xin-gang ZHUANG, Hong-bo LIU. Detection Efficiency Measurement of Silicon Single-photon Avalanche Detector Traceable Using Standard Detector[J]. Acta Photonica Sinica, 2019, 48(12): 1248006
    Download Citation