• Acta Photonica Sinica
  • Vol. 49, Issue 11, 190 (2020)
Yi-dan LI, Yuan CAO, Xu-dong WANG, Jie-jun ZHANG, Xin-huan FENG, and Bai-ou GUAN
Author Affiliations
  • Institute of Photonic Technology, Jinan University, Guangzhou511486, China
  • show less
    DOI: 10.3788/gzxb20204911.1149015 Cite this Article
    Yi-dan LI, Yuan CAO, Xu-dong WANG, Jie-jun ZHANG, Xin-huan FENG, Bai-ou GUAN. Doppler Frequency Shift Measuring Method Based on Dispersion-tuned Actively Mode-locking Technique[J]. Acta Photonica Sinica, 2020, 49(11): 190 Copy Citation Text show less
    Schematic diagram of dispersion-tuned actively mode-locked fiber laser
    Fig. 1. Schematic diagram of dispersion-tuned actively mode-locked fiber laser
    Relation between lasing wavelength and measurement frequency
    Fig. 2. Relation between lasing wavelength and measurement frequency
    Measurement range and measurement sensitivity at different cavity length, N=380, Dtotal =-995.6 ps/nm
    Fig. 3. Measurement range and measurement sensitivity at different cavity length, N=380, Dtotal =-995.6 ps/nm
    Measuerment sensitivity at different mode-locked order, L=300 m, Dtotal=-600 ps/nm
    Fig. 4. Measuerment sensitivity at different mode-locked order, L=300 m, Dtotal=-600 ps/nm
    Measurement sensitivity at different total dispersion with cavity length, L= 10 m, 50 m, 500 m, 1 500 m and 3 000 m, N=260
    Fig. 5. Measurement sensitivity at different total dispersion with cavity length, L= 10 m, 50 m, 500 m, 1 500 m and 3 000 m, N=260
    Measurement sensitivity at different total dispersion and cavity length with different mode-locked oeder,N1=10, N2=80,
    Fig. 6. Measurement sensitivity at different total dispersion and cavity length with different mode-locked oeder,N1=10, N2=80,
    Schematic diagram of frequency measurement setup based on DCF
    Fig. 7. Schematic diagram of frequency measurement setup based on DCF
    Spectra and relation between lasing wavelength and measurement frequency based on DCF
    Fig. 8. Spectra and relation between lasing wavelength and measurement frequency based on DCF
    Schematic diagram of the proposed frequency measurement setup based on LC-FBG
    Fig. 9. Schematic diagram of the proposed frequency measurement setup based on LC-FBG
    Spectra and relation between lasing wavelength and measurement frequency based on LC-FBG
    Fig. 10. Spectra and relation between lasing wavelength and measurement frequency based on LC-FBG
    Yi-dan LI, Yuan CAO, Xu-dong WANG, Jie-jun ZHANG, Xin-huan FENG, Bai-ou GUAN. Doppler Frequency Shift Measuring Method Based on Dispersion-tuned Actively Mode-locking Technique[J]. Acta Photonica Sinica, 2020, 49(11): 190
    Download Citation