• Acta Optica Sinica
  • Vol. 22, Issue 10, 1229 (2002)
[in Chinese]*, [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article Set citation alerts
    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Signal-to-Noise Ratio and Information Capacity of a Confocal Scanning Fluorescence Microscope[J]. Acta Optica Sinica, 2002, 22(10): 1229 Copy Citation Text show less
    References

    [1] Lukosz W. Optical systems with resolving powers exceeding the classical limit. J. Opt. Soc. Am., 1966, 56(11):1463~1472

    [2] Lukosz W. Optical systems with resolving powers exceeding the classical limit Ⅱ. J. Opt. Soc. Am., 1967, 57(7):932~942

    [3] Bendinelli M, Consortini A, Ronchi L. Degreas of freedom, and eigerfuntions, of the noisy image. J. Opt. Soc. Am., 1974, 64(11):1498~1502

    [4] Toraldo Di Francia G. Degrees of freedom of an image. J. Opt. Soc. Am., 1969, 59(7):799~804

    [5] Cox I J, Sheppard C J R. Information capacity and resolutions in an optical system. J. Opt. Soc. Am. (A), 1986, 3(8):1152~1158

    [6] Van der Voort H T M, Brakenhoff G J. Determination of the 3-dimensional optical properties of a confocal scanning laser microscope. Optik, 1988, 78(1):48~53

    [7] Sheppard C J R, Choudhury A. Image formation in the scanning microscope. Optica Acta, 1977, 24(10):1051~1073

    [8] Sheppard C J R, Wilson T. Image formation in scanning microscopes wits partiatly coherent source and detector. Optica Acta, 1978, 25(4):315~325

    [9] Strelbl N. Depth transfer by an imaging systems. Optica Acta, 1984, 31(11):1233~1241

    [10] Wilson T, Carlini A R. Depth discrimination criteria in confocal optical systems. Optik, 1987, 76(4):164~166

    [11] Van der Voort H T M, Brakenhoff G J. Determination of the 3-dimensional optical properties of a confocal scanning laser microscope. Optik, 1988, 78(2):48~53

    [12] Streibl N. Three-dimensional imaging by a microscope. J. Opt. Soc. Am. (A), 1985, 2(2):121~127

    [13] Drazic V. Dependence of two-and three-dimensional optical tranfer functions on pinhole radius in a coherent confocal microscope. J. Opt. Soc. Am. (A), 1992, 9(5):725~731

    [14] Sheppard C J R, Gu Min, Mao X Q. Three-dimensional coherent transfer function in a reflection-mode cofocal scanning microscope. Opt. Commun., 1991, 81(5):281~284

    [15] Visser T D, Wiersma S H. Electromagnetic description of image formation in confocal fluorescence microscopy. J. Opt. Soc. Am. (A), 1994, 11(2):599~608

    [16] Schmiff J M, Ben-Letaief K. Efficient Monte Carlo simulation of confocal microscopy in biological tissue. J. Opt. Soc. Am. (A), 1996, 13(5):952~961

    [17] Kempe M, Rudolph W, Welsch E. Comparative study of conical and heterodyne microscopy for imaging through scattering media. J. Opt. Soc. Am. (A), 1996, 13(1):46~52

    [18] Torok P, Wilson T. Rigorous theory for axial resolution in eonfocal microscopes. Opt. Commun., 1997, 137(1):127~135

    [19] Sandison D R, Piston D W, Williams R M et al.. Quantitative comparison of background rejection, signal-to-noise ratio, and resolution in conical and full-field laser scanning microscopes. Appl. Opt., 1995, 34(19):3576~3588

    [20] Sandison D R, Webb W W. Background rejection and signal-to-noise optimization in confocal and alternative fluorescence microscopes. Appl. Opt., 1994, 33(4):603~615

    [21] Dunn A K, Smithpeter C, Welch A J et al.. Sources of contrast in conical reflection imaging. Appl. Opt., 1996, 35(19):3441~3446

    [22] Cox I J, Sheppard C J R, Wilson T. Supes-nesolution by confocal fluorescent microscopy. Optik, 1982, 60(4):391~396

    [23] Sheppard C J R. The spatial frequency cut-off in three-dimensional imaging. Optik, 1986, 72(4):131~133

    [24] Sheppard C J R. The spational frequency cut-off in three-dimensional imaging Ⅱ. Optik, 1986, 74(3):128~129

    [25] Kimura S, Munakata C. Dependence of 3-D optical transfer functions on the pinhole radius in a fluorescent confocal optical microscope. Appl. Opt., 1990, 29(20):3007~3011

    [26] Amos W B, White J G, Fordham M. Use of confocal imaging in the study of biological structures. Appl. Opt., 1987, 26(16):3239~3243

    [27] Kimura S, Munakata C. Calculation of three-dimensional optical transfer function for a confocal scanning fluorescent microscope. J. Opt. Soc. Am.(A),1989,6:1015~1019

    [28] Nakamura O, Kawata S. Three-dimensional transfer function analysis of the tomographic capalility of a confocal fluorescence micoscope. J. Opt. Soc. Am. (A), 1990, 17(3):522~526

    [29] Tao Chunkan, Gao Wanrong, Bian Songling et al.. Laser confocal scanning microscope. Invention Patent of China. 98111188.2, 1998

    [32] Tao Chunkan, Gao Wanrong, Bian Songling et al.. Laser confocal scanning microscope. Invention Patent of China, Applying for in 2000, be authorized, 01108137.6

    [33] Tao Chunkan, Gao Wanrong, Bian Songling et al.. Laser confocal scanning microscope. New Practice Patent, Applying for in 2000, be authorized,01217876.4.

    CLP Journals

    [1] Hao Xiang, Kuang Cuifang, Wang Tingting, Liu Xu. Optimization of 0/π Phase Plate in Stimulated Emission Depletion Microscopy[J]. Acta Optica Sinica, 2011, 31(3): 318001

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Signal-to-Noise Ratio and Information Capacity of a Confocal Scanning Fluorescence Microscope[J]. Acta Optica Sinica, 2002, 22(10): 1229
    Download Citation