• Spectroscopy and Spectral Analysis
  • Vol. 42, Issue 4, 1139 (2022)
Pei-chao ZHENG*, Ran-ning LIU, Jin-mei WANG, Chu-hui FENG, Yu-tong HE, Mei-ni WU, and Yu-xin HE
Author Affiliations
  • Chongqing Municipal Level Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, College of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2022)04-1139-05 Cite this Article
    Pei-chao ZHENG, Ran-ning LIU, Jin-mei WANG, Chu-hui FENG, Yu-tong HE, Mei-ni WU, Yu-xin HE. Solution Cathode Glow Discharge-Atomic Emission Spectroscopy Coupled With Hydride Generation for Detecting Trace Mercury and Tin in Water[J]. Spectroscopy and Spectral Analysis, 2022, 42(4): 1139 Copy Citation Text show less
    Schematic diagram of hydride generation-solution cathode glow discharge (HG-SCGD) experimental device
    Fig. 1. Schematic diagram of hydride generation-solution cathode glow discharge (HG-SCGD) experimental device
    Characteristic emission lines of (a) Hg and (b) Sn
    Fig. 2. Characteristic emission lines of (a) Hg and (b) Sn
    (a) Influence of concentration of NaBH4, (b) solution pH and (c) argon flow rate on the signal intensity of Sn and Hg
    Fig. 3. (a) Influence of concentration of NaBH4, (b) solution pH and (c) argon flow rate on the signal intensity of Sn and Hg
    Influence of coexisting ions on the determination of (a) Sn and (b) Hg
    Fig. 4. Influence of coexisting ions on the determination of (a) Sn and (b) Hg
    元素R2RSD(%, n=10)LoD/(μg·L-1)
    Sn0.99632.926.85
    Hg0.99641.591.05
    Table 1. Calculation of detection limit of Sn and Hg
    方法LoD/(μg·L-1)文献
    SnHg
    PVG-SCGD-AES-1.6[6]
    SCGD-AES1 3007.0[12]
    CVG-ICP-OES-13[13]
    DBD-AAS10.60.35[14]
    CVG-AFS0.10.1[15]
    HG-SCGD6.851.05本方法
    Table 2. Comparison of the detection limits of Sn and Hg with different excitation sources
    元素水样种类添加浓度/
    (mg·L-1)
    测量浓度/
    (mg·L-1)
    回收
    率/%
    测量相对
    误差/%
    白云水库2019.8399.165.20
    Sn红岩水库2525.70102.782.97
    九曲河3030.92103.086.76
    白云水库11.01100.881.34
    Hg红岩水库1.51.52101.342.36
    九曲河0.50.4997.771.06
    Table 3. Calculation of recovery rate of actual water sample
    Pei-chao ZHENG, Ran-ning LIU, Jin-mei WANG, Chu-hui FENG, Yu-tong HE, Mei-ni WU, Yu-xin HE. Solution Cathode Glow Discharge-Atomic Emission Spectroscopy Coupled With Hydride Generation for Detecting Trace Mercury and Tin in Water[J]. Spectroscopy and Spectral Analysis, 2022, 42(4): 1139
    Download Citation