• Acta Optica Sinica
  • Vol. 40, Issue 7, 0712003 (2020)
Bihai Tu1、2、3、*, Jin Hong1、3、**, Pingping Yao1、3, Binhuan Meng1、3, Yinlin Yuan1、3, Miaomiao Zhang1、2、3, and Jianwen Weng1、2、3
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2University of Science and Technology of China, Hefei, Anhui 230026, China
  • 3Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • show less
    DOI: 10.3788/AOS202040.0712003 Cite this Article Set citation alerts
    Bihai Tu, Jin Hong, Pingping Yao, Binhuan Meng, Yinlin Yuan, Miaomiao Zhang, Jianwen Weng. Polarization Detection Performance of Directional Polarimetric Camera[J]. Acta Optica Sinica, 2020, 40(7): 0712003 Copy Citation Text show less
    Diagram of instrument system composition
    Fig. 1. Diagram of instrument system composition
    Diagram of on-orbit work
    Fig. 2. Diagram of on-orbit work
    Schematic diagram of DPC imaging system
    Fig. 3. Schematic diagram of DPC imaging system
    Schematic diagram of optical system
    Fig. 4. Schematic diagram of optical system
    865 nm polarized effect of lens
    Fig. 5. 865 nm polarized effect of lens
    910 nm polarized effect of lens
    Fig. 6. 910 nm polarized effect of lens
    Schematic diagram of performance measurement experiment setup
    Fig. 7. Schematic diagram of performance measurement experiment setup
    Measurement range of experiment
    Fig. 8. Measurement range of experiment
    Original image of DPC
    Fig. 9. Original image of DPC
    DOLP image of DPC
    Fig. 10. DOLP image of DPC
    Flow chart of data processing
    Fig. 11. Flow chart of data processing
    Diffusion function curve
    Fig. 12. Diffusion function curve
    2D diffusion function diagram
    Fig. 13. 2D diffusion function diagram
    Global coefficient matrix data. (a) Region (6,6); (b) region (7,8)
    Fig. 14. Global coefficient matrix data. (a) Region (6,6); (b) region (7,8)
    Stray light correction. (a) RGB image; (b) corrected data at wavelength of 865 nm; (c) ratio of stray light signal to effective data
    Fig. 15. Stray light correction. (a) RGB image; (b) corrected data at wavelength of 865 nm; (c) ratio of stray light signal to effective data
    DPC data preview
    Fig. 16. DPC data preview
    Polarization change curve of sunglint
    Fig. 17. Polarization change curve of sunglint
    Angle sensitivity curve
    Fig. 18. Angle sensitivity curve
    Data at wavelength of 865 nm. (a) Radiation intensity; (b) degree of polarization; (c) sunglint angle; (d) scattering angle
    Fig. 19. Data at wavelength of 865 nm. (a) Radiation intensity; (b) degree of polarization; (c) sunglint angle; (d) scattering angle
    Spectral response curve of 865 nm channel
    Fig. 20. Spectral response curve of 865 nm channel
    Polarization analysis of sunglint. (a) Simulation data; (b) DPC data; (c) deviation distribution; (d) polarization comparison scatter plot
    Fig. 21. Polarization analysis of sunglint. (a) Simulation data; (b) DPC data; (c) deviation distribution; (d) polarization comparison scatter plot
    Waveband /nmDOLP of different positions
    P1P2P3P4P5P6P7P8P9
    49000.10290.15280.20370.25450.30530.40630.50710.6073
    67000.10000.15000.20000.25000.30000.40000.50000.6000
    86500.09990.14850.19810.24760.29730.39660.49620.5961
    Table 1. Preset parameters of light source
    Preset DOLPMeasured value under different field-of-view angles
    45°30°15°-15°-30°-45°
    00.00360.00270.00450.00390.00340.00480.0063
    0.09990.09750.09630.09780.09540.09540.09540.0984
    0.14850.14600.14730.14560.14520.14880.14830.1477
    0.19810.19520.19730.19630.19300.19810.19750.1948
    0.24760.24780.24670.24600.24400.24750.24680.2480
    0.29730.29470.29730.29600.29310.29690.29550.2951
    0.39660.39500.39600.39560.39340.39610.39660.3954
    0.49620.49370.49520.49460.49350.49570.49580.4950
    0.59610.59500.59720.59530.59470.59630.59550.5938
    Table 2. Measured value at wavelength of 865 nm
    DOLPMeasured value under different zenith angles
    -55°-50°-45°-40°-35°-30°-25°
    By DPC0.19960.23750.28560.31040.32660.35260.3401
    By CE3180.20880.24890.29040.32110.34010.35710.3548
    P|0.00920.01140.00480.01070.01350.00450.0147
    DOLPMeasured value under different zenith angles
    -20°-15°-10°-5°10°
    By DPC0.34170.32150.30560.27460.24810.2110.1791
    By CE3180.35140.33820.31040.28220.24830.21140.1796
    P|0.00970.01670.00480.00760.00020.00040.0005
    Table 3. Measured value at wavelength of 865 nm
    Bihai Tu, Jin Hong, Pingping Yao, Binhuan Meng, Yinlin Yuan, Miaomiao Zhang, Jianwen Weng. Polarization Detection Performance of Directional Polarimetric Camera[J]. Acta Optica Sinica, 2020, 40(7): 0712003
    Download Citation