[1] P Gorenstein. Focusing X-ray optics for astronomy[J]. X-Ray Optics and Instrumentation, 2010, 2010: 109740.
[2] R Hudec, A Inneman, L Pina, et al.. Lobster eye X-ray telescope: Recent progress[C]. SPIE, 2003, 4851: 578-586.
[3] R Hudec. Kirkpatrick- Baez (kb) and Lobster eye (le) optics for astronomical and laboratory applications[J]. X- Ray Optics and Instrumentation, 2010, 2010: 139148.
[4] M E Bruner, R C Catura, J E Harvey, et al.. Design and performance predictions for the goes sxi telescope[C]. SPIE, 1998, 3442: 192-202.
[5] A Peele, W Zhang. Lobster-eye all-sky monitors: A comparison of one- and two-dimensional designs[J]. Review of Scientific Instruments, 1998, 69(7): 2785-2793.
[6] J R P Angel. Lobster eyes as X-ray telescope[J]. The Astrophysical Journal, 1979, 233: 364-373.
[7] Ni Qiliang. Optimization for spatial resolution and count rate of a far ultraviolet photon-counting imaging detector based on induced charge position-sensitive anode[J]. Acta Optica Sinica, 2014, 34(8): 0804001.
[9] Xiao Tiqiao, Xie Honglan, Deng Biao, et al.. Progresses of X-ray imaging methodology and its applications at Shanghai Synchrotron Radiation Facility[J]. Acta Optica Sinica, 2014, 34(1): 0100001.
[10] P Von Ballmoos, H Halloin, J Evrard, et al.. CLSIRE: First light for a gamma-ray lens[J]. Experimental Astronomy, 2006, 20(1): 253-267.
[11] A Peele, B E Allman, A Cimmino, et al.. Square capillary X-ray optics[C]. SPIE. 1994, 2279: 257-268.
[12] S W Wilkins, A W Stevenson, K A Nugent, et al.. On the concentration, focusing and collimation of X-rays and neutrons using microchannel plates and configurations of holes[J]. Review of Scientific Instruments, 1989, 60(6): 1026-1036.
[13] H N Chapman, K A Nugent, S W Wilkins. X-ray focusing using square channel capillary arrays[J]. Review of Scientific Instruments, 1991, 62(6): 1542-1561.
[14] H N Chapman, K A Nugent, S W Wilkins. X-ray focusing using cylindrical-channel capillary arrays[J]. Applied Optics, 1993, 32(31): 6316-6332.
[15] Liu Xiuping, Li Xiaoping, Sun Haifeng. X-ray pulsar signal de-noising using lifting scheme wavelet[J]. Acta Optica Sinica, 2013, 33(3): 0304002.
[16] Sun Tianxi, Liu Hehe, Liu Zhiguo, et al.. Application of confocal micro X-ray fluorescence technique based on polycapillary X-ray lens in analyzing medicine with capsule[J]. Acta Optica Sinica, 2014, 34(1): 0134001.
[17] Li Xu. Researches on the Image Properties of Extrem Ultraviolet Optical System Based on Square- Hole MCP[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2011: 14-30.