• Infrared and Laser Engineering
  • Vol. 51, Issue 6, 20210458 (2022)
Liuru Hu1, Xinming Tang2, Zhi Zhang1, Guoyuan Li2, Jiyi Chen2, Huaiqi Tian1, Shuaitai Zhang2、3, Junping Qiao1, and Xin Li1
Author Affiliations
  • 1The First Topographic Surveying Brigade of Ministry of Natural Resources of the People’s Republic of China, Xi’an 710054, China
  • 2Land Satellite Remote Sensing Application Center, Ministry of Natural Resources, Beijing 100048, China
  • 3Lanzhou Jiaotong University, Lanzhou 730070, China
  • show less
    DOI: 10.3788/IRLA20210458 Cite this Article
    Liuru Hu, Xinming Tang, Zhi Zhang, Guoyuan Li, Jiyi Chen, Huaiqi Tian, Shuaitai Zhang, Junping Qiao, Xin Li. Accuracy optimization and assessment of GF-7 satellite multi-source remote sensing data[J]. Infrared and Laser Engineering, 2022, 51(6): 20210458 Copy Citation Text show less

    Abstract

    The GF-7 satellite is the first sub-meter two-line-array stereo imaging satellite of China. It is equipped with two sets of laser altimeters and laser footprint cameras to capture multi-source remote sensing data simultaneously. In this paper, the multi-source remote sensing data of GF-7 satellite were used to promote the horizontal and vertical accuracy, which used laser altimetry data to optimize the vertical accuracy by skewness, median, linear polynomial and quadratic polynomial model, and the footprint image was used to optimize the horizontal accuracy in the first-order affine transformation method. Moreover, the accuracy of uncontrolled plane-elevation, laser elevation optimization, footprint-laser plane-elevation optimization and field-laser plane-elevation optimization were evaluated through the field control points. The experimental results show that the vertical accuracy of DSM can be improved significantly with the support of laser altimetry data. The mean vertical error of the DSM produced without GCPs is -4.268 m and the mean square error is 4.518 m. While the mean vertical error and mean square error of the DSM optimized by the median model are improved to -0.272 m and 1.508 m, and the mean vertical error and mean square error of the DSM optimized by linear model reach -0.320 m and 1.351 m. The horizontal accuracy of DOM can be improved by the footprint image. The mean horizontal error is optimized from 13.606 m to 5.341 m, and the mean square error is optimized from 13.626 m to 5.495 m.
    Liuru Hu, Xinming Tang, Zhi Zhang, Guoyuan Li, Jiyi Chen, Huaiqi Tian, Shuaitai Zhang, Junping Qiao, Xin Li. Accuracy optimization and assessment of GF-7 satellite multi-source remote sensing data[J]. Infrared and Laser Engineering, 2022, 51(6): 20210458
    Download Citation