• Acta Optica Sinica
  • Vol. 31, Issue 4, 412007 (2011)
Cui Tiangang1、2、*, Zhang Hongji1, Ma Wensheng1, and Chen Bo1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201131.0412007 Cite this Article Set citation alerts
    Cui Tiangang, Zhang Hongji, Ma Wensheng, Chen Bo. Improvements of Surface Profile Measuring Device for Wolter Type-I Mirror[J]. Acta Optica Sinica, 2011, 31(4): 412007 Copy Citation Text show less
    References

    [1] D. T. Luraev. Optical Aspheric Testing[M]. Yang Li Transl.. Beijing: Science Press, 1982. 9~19

    [2] Xie Yi, Chen Qiang, Wu Fan et al.. Concave aspherical surface testing with twin computer-generated holograms[J]. Acta Optica Sinica, 2008, 28(7): 1313~1317

    [3] Wang Xiaokun, Zheng Ligong, Zhang Xuejun. Testing convex aspheres by subaperture stitching interferometry[J]. Acta Optica Sinica, 2010, 30(7): 2022~2026

    [4] Zhao Wenchuan, Su Xianyu, Liu Yuankun et al.. Testing an aspheric mirror based on phase measuring deflectometry[J]. Chinese J. Lasers, 2010, 37(5): 1338~1341

    [5] Qian Shinan, Peter Z. Takacs. Equal optical path beamsplitter for a pencil beam interferometer and shearing interferometer[J]. Optical Engineering, 2003, 42(4): 929~934

    [6] D. Cocco, A. Bianco, G. Sostero. A second optic head for the ELETTRA long trace profiler[C]. SPIE, 2005, 5921: 59210L-1

    [7] Qian Jun, Lahsen Assoufid, Albert Macrander. Comparison of slope and height profiles for flat synchrotron X-ray mirrors measured with a long trace profiler and a PMI Fizeau interferometer[C]. SPIE, 2007, 6704: 67040C-1

    [8] Liu Bin, Wang Qiuping, Fu Shaojun. Investigation of long trace profiler for aspherical optics[J]. Laser & Optoelectronics Progress, 2006, 43(2): 46~53

    [9] Li Zhi, Zhao Yang, Li Dacheng et al.. A diffractive long trace profiler for large aspherical optics[J]. Acta Optica Sinica, 2002, 22(10): 1224~1228

    [10] Cui Tiangang, Wang Yonggang, Ma Dongmei et al.. Design of surface profile online measuring device used for Wolter Type I mirror[J]. Optics and Precision Engineering, 2010, 18(8): 1801~1806

    [11] Qian Shinan, Peter Z. Takacs. The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism[J]. Rev. Sci. Instrum, 1995, 66(3): 2562~2569

    [12] Ma Dongmei, Han Changyuan. System design of large flat mirror measurement based on pentagon prism scanning technique[J]. Electronic Measurement Technology, 2007, 30(11): 90~95

    [13] Kuang Cuifang, Feng Qibo, Liu Bin et al.. Influences on the deflection angle of the pentagonal prism due to dithering and fabrication angle error[J]. Optical Technique, 2004, 30(5): 616~622

    [14] Ma Dongmei, Liu Zhixiang, Ma Lei et al.. Influences of alignment error in pentaprism scanning system and fabrication angle error on measuring accuracy of optical surface[J]. Optics and Precision Engineering, 2008, 16(12): 2517~2523

    [15] Duan Jie, Sun Xiangyang, Cai Jinghai et al.. Applications research to PSD in the laser displacement detecting system[J]. Infrared and Laser Engineering, 2007, 36(z1): 281~284

    [16] Defeng Zheng, Xiangzhao Wang, Feng Tang. An improved method of angle measurement with a position sensitive detector[J]. Chin. Opt. Lett., 2007, 5(7): 403~406

    [17] Wang Heng, Li Jie, Kou Lili et al.. New method of projectile muzzle posture testing based on PSD[J]. Electronic Design Engineering, 2010, 18(4): 26~27

    [18] Fang Guanming, Cao Yiping, Zhou Liping. Analysis on the position sensitive detector positioning error caused by laser spot using new three-ray model[J]. Chinese J. Lasers, 2009, 36(4): 954~958

    CLP Journals

    [1] Li Shun, Gong Yan. Error Analysis and Correction during Measurement of Tube-Shaped Super-Smooth Mirrors Using Long Trace Profiler[J]. Acta Optica Sinica, 2011, 31(11): 1112001

    [2] Li Xu, He Fei, Li Da, Chen Bo. Influence of Structural Defect of Square-Hole Micro Channel Plate on Imaging Quality[J]. Acta Optica Sinica, 2012, 32(10): 1011001

    [3] Fu Yu, Cheng Xiangming, Yuan Shu, Xu Zhi. Error Analysis of Adjusting and Alignment for Multiband Spectrometer of One Meter Solar Telescope[J]. Chinese Journal of Lasers, 2012, 39(s2): 208007

    [4] Zhao Dachun, Chen Bo, Liu Peng, He Lingping. Image Quality Evaluation of Wolter X-Ray Nested Telescope[J]. Acta Optica Sinica, 2016, 36(3): 311002

    [5] Zhu Shou, Zhang Xiaohui. Analysis and Verification for Accuracy of Ritchey Angle in Flat Mirror Test[J]. Acta Optica Sinica, 2013, 33(6): 612001

    Cui Tiangang, Zhang Hongji, Ma Wensheng, Chen Bo. Improvements of Surface Profile Measuring Device for Wolter Type-I Mirror[J]. Acta Optica Sinica, 2011, 31(4): 412007
    Download Citation