• High Power Laser and Particle Beams
  • Vol. 33, Issue 9, 094006 (2021)
Guodong Gao1、2, Jianshe Cao1、2、*, Zhi Liu1, Yaoyao Du1, Qiang Ye1, Huizhou Ma1, Yanfeng Sui1、2, Junhui Yue1, Jun He1, Taoguang Xu1, Jing Yang1、2, Xing’er Zhang1、2, Xuhui Tang1、2, and Shujun Wei1、2
Author Affiliations
  • 1Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.11884/HPLPB202133.210202 Cite this Article
    Guodong Gao, Jianshe Cao, Zhi Liu, Yaoyao Du, Qiang Ye, Huizhou Ma, Yanfeng Sui, Junhui Yue, Jun He, Taoguang Xu, Jing Yang, Xing’er Zhang, Xuhui Tang, Shujun Wei. Study and implementation of automatic gain calibration method for 4-channel digital beam position monitor[J]. High Power Laser and Particle Beams, 2021, 33(9): 094006 Copy Citation Text show less

    Abstract

    The accuracy of beam position measurement is affected by the gain inconsistency of the four channels of the digital BPM. Based on the existing hardware and the requirement of beam position monitor (BPM) measurement accuracy, a design for automatic calibration of digital BPM sample data gain is implemented by Verilog language in the self-made electronics. Firstly, the system design of automatic gain calibration module is introduced. Secondly, the realization method of the module is described in detail, and the ADC data automatic gain calibration test platform is designed and built to verify the function of the automatic gain calibration module. Finally, the application of this design in BPM channel calibration is introduced. Test results show that this method achieves 4-channel gain consistency and makes the data amplitude after ADC sampling equal. This method effectively solves the measurement bias caused by channel gain inconsistency and the difficulty of ADC data amplitude calibration in engineering application. It will play an important role in the automatic channel calibration of BPM system.
    Guodong Gao, Jianshe Cao, Zhi Liu, Yaoyao Du, Qiang Ye, Huizhou Ma, Yanfeng Sui, Junhui Yue, Jun He, Taoguang Xu, Jing Yang, Xing’er Zhang, Xuhui Tang, Shujun Wei. Study and implementation of automatic gain calibration method for 4-channel digital beam position monitor[J]. High Power Laser and Particle Beams, 2021, 33(9): 094006
    Download Citation