• Acta Optica Sinica
  • Vol. 39, Issue 3, 0306004 (2019)
Jian Geng1, Xiaojun Zhu1、2、3、*, Guoan Zhang1、*, Chen Xu1、2, Yancheng Ji1, Li Jin1, and Juan Cao1、2
Author Affiliations
  • 1 School of Electronics and Information, Nantong University, Nantong, Jiangsu 226019, China
  • 2 Nantong Research Institute for Advanced Communication Technologies, Nantong, Jiangsu 226000, China
  • 3 Key Lab of Advanced Optical Manufacturing Technologies of Jiangsu Province, Soochow University, Suzhou, Jiangsu 215006, China
  • show less
    DOI: 10.3788/AOS201939.0306004 Cite this Article Set citation alerts
    Jian Geng, Xiaojun Zhu, Guoan Zhang, Chen Xu, Yancheng Ji, Li Jin, Juan Cao. Bandwidth Tunable Microfiber-Assisted Mach-Zehnder Interferometer Based on Tapered-Drawing Fiber Bragg Grating[J]. Acta Optica Sinica, 2019, 39(3): 0306004 Copy Citation Text show less
    Schematic of experimental setup for fused tapering by hydrogen oxygen flame
    Fig. 1. Schematic of experimental setup for fused tapering by hydrogen oxygen flame
    Structure of tapered grating
    Fig. 2. Structure of tapered grating
    Transmission spectrum of MZI with FBG after fused tapering
    Fig. 3. Transmission spectrum of MZI with FBG after fused tapering
    Λ(z) after tapering
    Fig. 4. Λ(z) after tapering
    Relationship between n(z) and z
    Fig. 5. Relationship between n(z) and z
    Transmission spectra of MZI under different NaCl solution concentrations. (a) 1%; (b) 5.76%; (c) 7.88%; (d) 10.16%; (e) 13.11%; (f) 16.22%
    Fig. 6. Transmission spectra of MZI under different NaCl solution concentrations. (a) 1%; (b) 5.76%; (c) 7.88%; (d) 10.16%; (e) 13.11%; (f) 16.22%
    Transmission spectra under different solution concentrations of NaCl
    Fig. 7. Transmission spectra under different solution concentrations of NaCl
    Relationship between bandwidth and refractive index as well as its corresponding linear fitting curve
    Fig. 8. Relationship between bandwidth and refractive index as well as its corresponding linear fitting curve
    Transmission spectra of four hypothetical structures. (a) Simulated and experimental transmission spectra of tapered-drawing fiber grating; (b) transmission spectra of SMF with tapering lengths of 0, 19.831, 22.244 mm; (c) reflectance spectra of long grating FBG before and after tapering; (d) simulated transmission spectrum of LPG-SMF-LPG
    Fig. 9. Transmission spectra of four hypothetical structures. (a) Simulated and experimental transmission spectra of tapered-drawing fiber grating; (b) transmission spectra of SMF with tapering lengths of 0, 19.831, 22.244 mm; (c) reflectance spectra of long grating FBG before and after tapering; (d) simulated transmission spectrum of LPG-SMF-LPG
    Jian Geng, Xiaojun Zhu, Guoan Zhang, Chen Xu, Yancheng Ji, Li Jin, Juan Cao. Bandwidth Tunable Microfiber-Assisted Mach-Zehnder Interferometer Based on Tapered-Drawing Fiber Bragg Grating[J]. Acta Optica Sinica, 2019, 39(3): 0306004
    Download Citation