• Laser & Optoelectronics Progress
  • Vol. 57, Issue 5, 051701 (2020)
Da Zou1, Kexin Wang2, Gangjun Liu3、4, Qiushi Ren1、3、4, and Yanye Lu1、*
Author Affiliations
  • 1Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871, China
  • 2Department of Ophthalmology, Peking University First Hospital, Beijing 100034, China
  • 3Institute of Biomedical Engineering, Peking University Shenzhen Graduate School, Shenzhen, Guangdong 518055, China
  • 4Shenzhen Bay Laboratory, Shenzhen, Guangdong 518052, China
  • show less
    DOI: 10.3788/LOP57.051701 Cite this Article Set citation alerts
    Da Zou, Kexin Wang, Gangjun Liu, Qiushi Ren, Yanye Lu. Noninvasive Measurement of Retinal Oxygen Saturation and Vessel Diameter Changes in Diabetes Mellitus Patients[J]. Laser & Optoelectronics Progress, 2020, 57(5): 051701 Copy Citation Text show less
    References

    [1] NCD Risk Factor Collaboration. Worldwide trends in diabetes since 1980: a pooled analysis of 751 population-based studies with 4.4 million participants[J]. Lancet (London, England), 387, 1513-1530(2016).

    [2] Zheng Y, Ley S H, Hu F B. Global aetiology and epidemiology of type 2 diabetes mellitus and its complications[J]. Nature Reviews Endocrinology, 14, 88-98(2018).

    [3] Zimmet P, Alberti K G, Magliano D J et al. Diabetes mellitus statistics on prevalence and mortality: facts and fallacies[J]. Nature Reviews Endocrinology, 12, 616-622(2016).

    [4] Hu C, Jia W P. Diabetes in China: epidemiology and genetic risk factors and their clinical utility in personalized medication[J]. Diabetes, 67, 3-11(2018).

    [5] Wang L M, Gao P, Zhang M et al. Prevalence and ethnic pattern of diabetes and prediabetes in China in 2013[J]. JAMA, 317, 2515-2523(2017).

    [6] Hardarson S H, Harris A, Karlsson R A et al. Automatic retinal oximetry[J]. Investigative Opthalmology & Visual Science, 47, 5011-5016(2006).

    [7] Schweitzer D, Hammer M, Kraft J et al. In vivo measurement of the oxygen saturation of retinal vessels in healthy volunteers[J]. IEEE Transactions on Biomedical Engineering, 46, 1454-1465(1999).

    [8] Lin L L, Dong Y M, Zong Y et al. Study of retinal vessel oxygen saturation in ischemic and non-ischemic branch retinal vein occlusion[J]. International Journal of Ophthalmology, 9, 99-107(2016).

    [9] Jeppesen S K, Bek T. The retinal oxygen saturation measured by dual wavelength oximetry in larger retinal vessels is influenced by the linear velocity of the blood[J]. Current Eye Research, 44, 46-52(2019).

    [10] Zheng Q, Zong Y, Li L et al. Retinal vessel oxygen saturation and vessel diameter in high myopia[J]. Ophthalmic and Physiological Optics, 35, 562-569(2015).

    [11] Beach J M, Schwenzer K J, Srinivas S et al. Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation[J]. Journal of Applied Physiology, 86, 748-758(1999).

    [12] Geirsdottir A, Palsson O, Hardarson S H et al. Retinal vessel oxygen saturation in healthy individuals[J]. Investigative Ophthalmology & Visual Science, 53, 5433-5442(2012).

    [13] Jørgensen C, Bek T. Increasing oxygen saturation in larger retinal vessels after photocoagulation for diabetic retinopathy[J]. Investigative Ophthalmology & Visual Science, 55, 5365-5369(2014).

    [14] Shimazaki T, Hirooka K, Nakano Y et al. Oxygen venular saturation correlates with a functional loss in primary open-angle glaucoma and normal-tension glaucoma patients[J]. Acta Ophthalmologica, 96, e304-e308(2018).

    [15] Einarsdottir A B, Olafsdottir O B, Hjaltason H et al. Retinal oximetry is affected in multiple sclerosis[J]. Acta Ophthalmologica, 96, 528-530(2018).

    [16] Šínová I. Rˇehák J, Nekolová J, et al. Correlation between ischemic index of retinal vein occlusion and oxygen saturation in retinal vessels[J]. American Journal of Ophthalmology, 188, 74-80(2018).

    [17] Jeppesen S K, Bek T. Retinal oxygen saturation correlates with visual acuity but does not predict outcome after anti-VEGF treatment in central retinal vein occlusion[J]. Investigative ophthalmology & visual science, 58, 2498-2502(2017).

    [18] Hardarson S H, Stefánsson E. Oxygen saturation in central retinal vein occlusion[J]. American Journal of Ophthalmology, 150, 871-875(2010).

    [19] Hardarson S H, Stefánsson E. Oxygen saturation in branch retinal vein occlusion[J]. Acta Ophthalmologica, 90, 466-470(2012).

    [20] Hardarson S H, Elfarsson A, Agnarsson B A et al. Retinal oximetry in central retinal artery occlusion[J]. Acta Ophthalmologica, 91, 189-190(2013).

    [21] Lim L S, Tan L, Perera S. Retinal vessel oxygen saturation increases after vitrectomy[J]. Investigative Ophthalmology & Visual Science, 55, 3851-3856(2014).

    [22] Osaka R, Nakano Y, Takasago Y et al. Retinal oximetry in branch retinal vein occlusion[J]. Acta Ophthalmologica, 97, e896-e901(2019).

    [23] Ueda-Consolvo T, Fuchizawa C, Otsuka M et al. Analysis of retinal vessels in eyes with retinitis pigmentosa by retinal oximeter[J]. Acta Ophthalmologica, 93, e446-e450(2015).

    [24] Traustason S, Jensen A S, Arvidsson H S et al. Retinal oxygen saturation in patients with systemic hypoxemia[J]. Investigative Ophthalmology & Visual Science, 52, 5064-5067(2011).

    [25] Palsson O, Geirsdottir A, Hardarson S H et al. Retinal oximetry images must be standardized: a methodological analysis[J]. Investigative Ophthalmology & Visual Science, 53, 1729-1733(2012).

    [26] Blondal R, Sturludottir M K, Hardarson S H et al. Reliability of vessel diameter measurements with a retinal oximeter[J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 249, 1311-1317(2011).

    [27] Wong T Y, Shankar A, Klein R et al. Retinal arteriolar narrowing, hypertension, and subsequent risk of diabetes mellitus[J]. Archives of Internal Medicine, 165, 1060-1065(2005).

    [28] Pournaras C J, Rungger-Brändle E, Riva C E et al. Regulation of retinal blood flow in health and disease[J]. Progress in Retinal and Eye Research, 27, 284-330(2008).

    Da Zou, Kexin Wang, Gangjun Liu, Qiushi Ren, Yanye Lu. Noninvasive Measurement of Retinal Oxygen Saturation and Vessel Diameter Changes in Diabetes Mellitus Patients[J]. Laser & Optoelectronics Progress, 2020, 57(5): 051701
    Download Citation