[1] Qiu Aici, Cai Hansheng, Li Junna. New power system should be impervious to strong EMP threat (digital grid)[N]. China Energy News, 20210802(04)
[2] National Energy Administration. Notice of the National Energy Administration on the issuance of the “14th FiveYear Plan of Action f Safe Production of Electricity”[EBOL]. (20211208). http:zfxxgk.nea.gov.cn20211208c_1310442211.htm.
[3] Gilbert J, Kappenman J, Radasky W, et al. The latetime (E3) highaltitude electromagic pulse (HEMP) its impact on the U. S. power grid[R]. Goleta: Oak Ridge National Labaty, 2010.
[6] Zhou Yuxiang. Simulation study on the influence of the late effect of HEMP on the traction power supply system[D]. Shijiazhuang: Shijiazhuang Tiedao University, 2021
[7] Wang Jianguo, Niu Shengli, Zhang Dianhui, et al. Parameter manual of highaltitude nuclear explosion effects[M]. Beijing: Atomic Energy Press, 2010
[8] Brouillette D. Response to the summmy of conclusions f the December 21, 2020 PSG meeting on benchmarks f electromagic pulses (EMP)[R]. Department of Energy, 2021.
[9] Feng Hanliang, Wu Xiaolong, Li Yong. Review of the U. S. Congress’ commission to assess the threat to the United States from electromagnetic pulse attack and its reports[J]. Equipment Environmental Engineering, 17, 132-137(2020).
[11] Xu Ting. Study on the influence of earth conductivity model on geoelectric induced field[D]. Xi’an: Xi’an University of Science Technology, 2018
[18] Zhang Bing. Research on effects of geomagically induced current on large power transfmers[D]. Beijing: Nth China Electric Power University (Beijing), 2010
[19] Liu Lianguang, Zhang Bing, Xiao Xiangning. Analysis of transformer exciting current harmonic under geomagnetically induced current[J]. Transformer, 47, 43-46,68(2010).
[20] Li Xiaodong, Zong Wei, Liu Lianguang. Dynamic simulation of transformer harmonic effect under GIC[J]. East China Electric Power, 42, 101-105(2014).
[21] Hu Yidan, Li Junhao. Analysis of excitation characteristics of transformers with different core shapes under severe DC bias[J]. Energy Reports, 8, 1176-1183(2022).
[23] Liu Jiaomin, Zhu Xi, Liu Hongzheng, . Calculation methods for reactive power loss of transformers due to geomagnetically induced current[J]. High Voltage Engineering, 44, 2284-2291(2018).
[24] Berge J, Varma R K, Marti L. Labaty validation of the relationship between geomagically induced current (GIC) transfmer absbed reactive power[C]2011 IEEE Electrical Power Energy Conference. 2011: 491495.
[27] Dong Xuzhu, Liu Yilu, Kappenman J G. Comparative analysis of exciting current harmonics reactive power consumption from GIC saturated transfmers[C]2001 IEEE Power Engineering Society Winter Meeting. 2001: 318322.
[28] Wang Zezhong, Huang Tianchao. Quantitative analysis of geomagnectically induced current-Q relation of UHV transformer[J]. Transactions of China Electrotechnical Society, 35, 4709-4716(2020).
[29] Yang Yifan, Liu Minzhou, Xie Yanzhao, . Simulation research on reactive power loss characteristic of 500kV transformer under late-time high-altitude electromagnetic pulses[J]. Transactions of China Electrotechnical Society, 39, 267-277(2024).
[33] Wang Zezhong, Tan Ruijuan, Liu Lianguang, . DC bias calculation and characteristics analysis of reactive power for the UHV transformer[J]. High Voltage Apparatus, 53, 101-107(2017).
[34] Gong Ruohan, Ruan Jiangjun, Liao Caibo, et al. 3D coupled electromagicfluidthermal analysis of 220kV threephase threelimb transfmer under DC bias[C]2016 IEEE Conference on Electromagic Field Computation (CEFC). 2016: 1.
[35] Yan Xiaoli, Dong Xia, Han Guozheng, et al. Study of transfmer loss temperature rise under DC bias magism based on finite element method[C]2023 IEEEIAS Industrial Commercial Power System Asia (I&CPS Asia). 2023: 429434.
[36] Wang Zezhong, Li Mingyang, Xuan Mengzhen, . Temperature rise test and simulation of single-phase four-column transformer under DC-bias[J]. Transactions of China Electrotechnical Society, 36, 1006-1013(2021).
[39] Zhu Tao, Wang Fenghua. Calculation of temperature rise of large transformer under geomagnetically induced current[J]. Transactions of China Electrotechnical Society, 37, 1915-1925(2022).
[40] Zhang Shuqi, Wang Ke, Li Jinzhong, . Tests of DC bias key performances of power transformer with single-phase three-limb core under no-load and rated-load conditions[J]. Proceedings of the CSEE, 39, 4334-4344(2019).
[41] Girgis R, Vedante K. Effects of GIC on power transfmers power systems[C]PES T&D 2012. 2012: 18.
[42] Hton R. Magohydrodynamic electromagic pulse assessment of the continental U. S. electric grid[R]. Palo Alto: Electric Power Research Institute, 2017.
[43] Chen Peilu. Research on the effects of DC magic bias caused by HVDCGIC on differential protection[D]. Baoding: Nth China Electric Power University, 2014
[45] Ma Shumin, Rong Zirui, Lin Xiangning, et at. Analysis and countermeasures of relay protection false rejection mechanism under the influence of DC bias[J]. Power System Protection and Control, 50, 86-98(2022).
[47] Lauby M G, Rollison E. Effects of geomagic disturbances on the bulk power system[R]. Atlanta: NERC, 2012.
[50] Huang Min, Guo Qianwen, Tong Chongli, . Mechanism analysis of DC-bias increasing the risk of commutation failure[J]. Journal of Huazhong University of Science and Technology (Natural Science Edition), 42, 102-106(2014).
[55] Li Mingyang, Zhang Junshuang, Li Haiming, . Loss and temperature rise test and analysis on 500 kV single-phase auto-transformer under no-load DC bias[J]. High Voltage Apparatus, 57, 132-139(2021).
[56] DTL 17992018, The method of ability to withst DC bias test f power transfmers[S]
[57] Barnes P R, Tesche F, Mcconnell B W, et al. MHDEMP analysis protection[R]. Alexria: Defense Nuclear Agency, 1993.
[58] Li Mingyang. Research on loss temperature rise acteristics of UHV transfmers under DC bias[D]. Beijing: Nth China Electric Power University (Beijing), 2021
[59] Li Bing, Wang Zezhong, Liu Haibo, . Experiment on vibro-acoustic characteristic of 500kV single-phase transformer under DC-bias[J]. Transactions of China Electrotechnical Society, 36, 2801-2811(2021).
[61] Dethlefsen R. Design concepts f a pulse power test facility to simulate EMP surges. Part II. Slow pulses[R]. San Diego: Maxwell Labaties, 1985.
[62] Foster J S Jr, Gjelde E, Graham W R, et al. Rept of the commission to assess the threat to the united states from electromagic pulse (EMP) attack. Volume 1: executive rept[R]. EMP Commission, 2004.
[63] Foster J S Jr, Gjelde E, Graham W R, et al. Rept of the commission to assess the threat to the united states from electromagic pulse (EMP) attack: critical national infrastructures[R]. EMP Commission, 2008.
[64] Rept of the commission to assess the threat to the united states from electromagic pulse (EMP) attack. Volume I: assessing the threat from electromagic pulse (EMP) executive rept[R]. EMP Commission, 2017.
[65] Overbye T J, Shetye K S, Hughes Y Z, et al. Preliminary consideration of voltage stability impacts of geomagically induced currents[C]2013 IEEE Power & Energy Society General Meeting. 2013: 15.
[66] Hutchins T. Modeling, simulation, mitigation of the impacts of the late time (E3) highaltitude electromagic pulse on power systems[D]. Urbana: University of Illinois at UrbanaChampaign, 2016.
[67] Overbye T J, Wert J, Shetye K S, et al. Delaunay triangulation based widearea visualization of electric transmission grids[C]2021 IEEE Kansas Power Energy Conference (KPEC). 2021: 16.
[68] Bie Zhaohong, Lin Yanling, Qiu Aici. Concept and research prospects of power system resilience[J]. Automation of Electric Power Systems, 39, 1-9(2015).
[71] Li Gengfeng, Sun Shaohua, Bie Zhaohong, . Review on optimal configuration and flexible scheduling research of energy storage for resilience improvement of new power system[J]. High Voltage Engineering, 49, 4084-4095(2023).
[72] Li Minghao, Yang Qiming, Li Gengfeng, . Two-stage power supply restoration strategy of resilient distribution network based on coordination of multiple distributed resources in typhoon scenario[J]. High Voltage Engineering, 50, 93-104(2024).