• Infrared and Laser Engineering
  • Vol. 51, Issue 3, 20210148 (2022)
Haiyuan Cao, Wei Li, Yimin Lu, Hua Chu, and Chaowei Mi
Author Affiliations
  • Opto-electronics Department, Ordnance Noncommissioned Officers School, Army Engineering University, Wuhan 430075, China
  • show less
    DOI: 10.3788/IRLA20210148 Cite this Article
    Haiyuan Cao, Wei Li, Yimin Lu, Hua Chu, Chaowei Mi. Effectiveness evaluation for double-station passive location based on CCD[J]. Infrared and Laser Engineering, 2022, 51(3): 20210148 Copy Citation Text show less
    Diagram of double-station location based on CCD
    Fig. 1. Diagram of double-station location based on CCD
    Diagram of reconnoiter by eyes and CCD
    Fig. 2. Diagram of reconnoiter by eyes and CCD
    Curve of contrast and detection probability with distance
    Fig. 3. Curve of contrast and detection probability with distance
    Location range of double-station based on CCD
    Fig. 4. Location range of double-station based on CCD
    Location distance of double-station based on CCD
    Fig. 5. Location distance of double-station based on CCD
    Mean value and Std. deviation of location error
    Fig. 6. Mean value and Std. deviation of location error
    Distance between CCD’s/kmMaximum location width/kmMaximum location range/km Mean of location deviation/m Std. of location deviation/m
    2.530.515.890.988.6
    5.028.015.848.258.2
    7.525.515.724.621.5
    10.023.015.623.918.4
    12.520.515.218.815.4
    15.018.014.614.210.5
    17.515.513.914.310.1
    20.013.013.115.610.3
    22.510.512.022.711.2
    25.08.010.827.514.1
    27.55.59.135.424.9
    30.03.06.948.336.2
    32.50.52.9322.3273.5
    Table 1. Location range and deviation vs. the distance of double station
    Haiyuan Cao, Wei Li, Yimin Lu, Hua Chu, Chaowei Mi. Effectiveness evaluation for double-station passive location based on CCD[J]. Infrared and Laser Engineering, 2022, 51(3): 20210148
    Download Citation