• Acta Optica Sinica
  • Vol. 37, Issue 2, 230005 (2017)
Liu Bingjie*, Han Tongshuai, Guo Chao, Sun Di, and Liu Jin
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201737.0230005 Cite this Article Set citation alerts
    Liu Bingjie, Han Tongshuai, Guo Chao, Sun Di, Liu Jin. Sensitivity Analysis of Near-Infrared Diffuse Reflectance Spectroscopic Measurement in Turbid Medium[J]. Acta Optica Sinica, 2017, 37(2): 230005 Copy Citation Text show less
    References

    [2] Chu Xiaoli, Lu Wanzhen. Research and application progress of near infrared spectroscopy analytical technology in China in the past five years[J]. Spectroscopy and Spectral Analysis, 2014, 34(10): 2595-2605.

    [3] Qu J H, Liu D, Cheng J H, et al. Applications of near-infrared spectroscopy in food safety evaluation and control: a review of recent research advances[J]. Critical Reviews in Food Science and Nutrition, 2015, 55(13): 1939-1954.

    [4] Davies D J, Su Z, Clancy M T, et al. Near-infrared spectroscopy in the monitoring of adult traumatic brain injury: a review[J]. Journal of Neurotrauma, 2015, 32(13): 933-941.

    [5] Tsuchikawa S, Kobori H. A review of recent application of near infrared spectroscopy to wood science and technology[J]. Journal of Wood Science, 2015, 61(3): 213-220.

    [6] Cui C J, Cai W S, Shao X G. Near-infrared diffuse reflectance spectroscopy with sample spots and chemometrics for fast determination of bovine serum albumin in micro-volume samples[J]. Chinese Chemical Letters, 2013, 24(1): 67-69.

    [7] Liu J, Liu R, Xu K X. Accuracy of noninvasive glucose sensing based on near-infrared spectroscopy[J]. Applied Spectroscopy, 2015, 69(11): 1313-1318.

    [8] Luo Y H, Huang F R, Li S P, et al. Detection limit of glucose concentration with near-infrared absorption and scattering spectroscopy[J]. Chinese Physics Letters, 2008, 25(3): 1117-1119.

    [9] Liu Y, Ning Y, Cai W, et al. Micro-analysis by near-infrared diffuse reflectance spectroscopy with chemometric methods[J]. Analyst, 2013, 138(21): 6617-6622.

    [10] Bouchard J P, Veileux I, Jedidi R, et al. Reference optical phantoms for diffuse optical spectroscopy. Part 1 - error analysis of a time resolved transmittance characterization method[J]. Optics Express, 2010, 18(11): 11495-11507.

    [11] Li Qingbo, Xu Kexin, Wang Yan. Primary discussion on prerequisites to noninvasive blood glucose[J]. Journal of Tianjin University, 2003, 36(2): 139-142.

    [12] Luo Yunhan, Chen Zhe, Chen Xingdan. Detection limit of glucose concentration in noninvasive sensing with near infrared spectroscopy[J]. Optics and Precision Engineering, 2008, 16(5): 784-788.

    [13] Li Gang, Zhao Zhe, Wang Huiquan, et al. The concentration resolution of complex liquid spectrometry analysis and the effect of concentration distribution[J]. Spectroscopy and Spectral Analysis, 2012, 32(4): 1077-1080.

    [14] Fu Bo, Hu Yongxiang, Liu Rong, et al. Near-infrared measurement with medium concentration sample as reference[J]. Acta Optica Sinica, 2016, 36(2): 0230003.

    [15] Faber N M, Buydens L M C, Kateman G. Generalized rank annihilation method. II: bias and variance in the estimated eigenvalues[J]. Journal of Chemometrics, 1994, 8(3): 181-203.

    [16] de Groot P J, Postma G J, Melssen W J, et al. Influence of wavelength selection and data preprocessing on near-infrared-based classification of demolition waste[J]. Applied Spectroscopy, 2001, 55(2): 173-181.

    [17] McShane M J, Coté G L, Spiegelman C H. Assessment of partial least-squares calibration and wavelength selection for complex near-infrared spectra[J]. Applied Spectroscopy, 1998, 52(6): 878-884.

    [18] Leardi R, Seasholtz M B, Pell R J. Variable selection for multivariate calibration using a genetic algorithm: prediction of additive concentrations in polymer films from Fourier transform-infrared spectral data[J]. Analytica Chimica Acta, 2002, 461(2): 189-200.

    [19] Yang Y, Chen W L, Shi Z Z, et al. Reference point of floating-reference method for blood glucose sensing[J]. Chinese Optics Letters, 2010, 8(4): 421-424.

    [20] Wang Zhulou, Zhang Wanjie, Li Chenxi, et al. The validation of the effect of correcting spectral background changes based on floating reference method by simulation[J]. Spectroscopy and Spectral Analysis, 2015, 35(2): 547-551.

    [21] Wang Jiao, Liu Rong, Yu Xuyao, et al. Research on existence of floating reference position in human body[J]. Acta Optica Sinica, 2016, 36(6): 0630003.

    [22] Dong Yanfei, Lu Qipeng, Ding Haiquan, et al. Study on the best detector-distance of noninvasive biochemical examination by Monte Carlo simulation[J]. Spectroscopy and Spectral Analysis, 2014, 34(4): 942-946.

    [23] Xu Kexin, Gao Feng, Zhao Huijuan. Biomedical photonics[M]. Beijing: Science Press, 2011: 42-49.

    [24] Troy T L, Thennadil S N. Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm[J]. Journal of Biomedical Optics, 2001, 6(2): 167-176.

    Liu Bingjie, Han Tongshuai, Guo Chao, Sun Di, Liu Jin. Sensitivity Analysis of Near-Infrared Diffuse Reflectance Spectroscopic Measurement in Turbid Medium[J]. Acta Optica Sinica, 2017, 37(2): 230005
    Download Citation