Zhentao Liu, Xia Shen, Honglin Liu, Hong Yu, Shensheng Han. Lensless Wiener–Khinchin telescope based on second-order spatial autocorrelation of thermal light[J]. Chinese Optics Letters, 2019, 17(9): 091101
Copy Citation Text
The resolution of a conventional imaging system based on first-order field correlation can be directly obtained from the optical transfer function. However, it is challenging to determine the resolution of an imaging system through random media, including imaging through scattering media and imaging through randomly inhomogeneous media, since the point-to-point correspondence between the object and the image plane in these systems cannot be established by the first-order field correlation anymore. In this Letter, from the perspective of ghost imaging, we demonstrate for the first time, to the best of our knowledge, that the point-to-point correspondence in these imaging systems can be quantitatively recovered from the second-order correlation of light fields, and the imaging capability, such as resolution, of such imaging schemes can thus be derived by analyzing second-order autocorrelation of the optical transfer function. Based on this theoretical analysis, we propose a lensless Wiener–Khinchin telescope based on second-order spatial autocorrelation of thermal light, which can acquire the image of an object by a snapshot via using a spatial random phase modulator. As an incoherent imaging approach illuminated by thermal light, the lensless Wiener–Khinchin telescope can be applied in many fields such as X-ray astronomical observations.
Imaging resolution is an important metric of various imaging systems, including microscopy, astronomy, and photography[1–4]. It is well known that the operating wavelength and the aperture of an imaging system are two key parameters for resolution[1,2]. Generally speaking, in conventional imaging systems, where a point-to-point correspondence between the object and the image plane can be established based on first-order field correlation, the resolution can be directly analyzed from a transmission function of the imaging system, and it is proportional to . Therefore, a shorter wavelength and/or a larger aperture is required for a higher resolution; however, a large aperture leads to demanding requirements on the manufacture of a traditional monolithic optical telescope, which is arduous, especially for X-ray imaging.
Recently, emerging systems through random media[5–20] have been built, which include imaging through scattering media and imaging through randomly inhomogeneous media. However, it is challenging to determine the resolution of these imaging systems, since the point-to-point correspondence between the object and the image plane in these systems cannot be established by the first-order correlation anymore. In this Letter, we show that when the statistical properties of the random media are known as a priori, the resolution of such an imaging system can be deduced by analyzing the second-order correlation of light fields from the prospective of ghost imaging (GI)[10,21–23]. Based on this theoretical analysis, a lensless Wiener–Khinchin telescope is further proposed based on second-order spatial autocorrelation of thermal light, which can acquire the image of the object in a single shot by using a spatial random phase modulator. We demonstrate that different from conventional imaging systems, the resolution of imaging systems through random media not only depends on the aperture of random media, but also on the statistical properties of it in a theoretical and experimental way. The influence of signal bandwidth is also investigated. Moreover, experimental results for both far away and equivalent infinity far away imaging prove the feasibility of the proposed lensless Wiener–Khinchin telescope in astronomical observations.
The proposed lensless Wiener–Khinchin telescope (Fig. 1) consists of a spatial random phase modulator and a charge-coupled device (CCD) detector, which detects the intensity distribution of the modulated light field. The object is illuminated by a thermal light source.
Sign up for Chinese Optics Letters TOC. Get the latest issue of Chinese Optics Letters delivered right to you!Sign up now
Figure 1.Schematic of a lensless Wiener–Khinchin telescope. is the diameter of the spatial random phase modulator. and are distances from the object and detection planes to the spatial random phase modulator, respectively.
For diffraction imaging[24], the spatial intensity distribution detected by the CCD detector is where and are the time-variant complex amplitude in the object plane, and are the point-spread function (PSF) of the imaging system, is the time average, is the coordinate in the detection plane, and and are the coordinates in the object plane.
Since the target of a telescope is illuminated by perfectly incoherent thermal light, we have[24]where is the intensity distribution in the object plane, and is a real constant. Taking Eq. (2) into Eq. (1) yields where is the incoherent intensity impulse response function.
Considering the spatial random phase modulator for thermal light as an ergodic process, the second-order spatial autocorrelation of the measured light field is[25,26]where is the spatial average over the coordinate , and is the ensemble average of the spatial random phase modulator. Plugging Eq. (3) into Eq. (4), we have where is the second-order correlation function of PSFs between and .
According to the central limit theorem[27], the light field through the spatial random phase modulator obeys the complex circular Gaussian distribution in the spatial domain[27], and can be written as[28]with , and is defined as the normalized second-order correlation of PSFs.
For Fresnel diffraction, the PSF of a lensless Wiener–Khinchin telescope is where and are the pupil function and the transmission function of the spatial random phase modulator, respectively, while and are the height and the refractive index of the spatial random phase modulator, respectively.
Substituting Eq. (9) into Eq. (8) yields
In general, assuming the height ensemble average of the spatial random phase modulator obeys the following mathematical form[29]: where and are the height standard deviation and the transverse correlation length of the spatial random phase modulator, respectively. Thus, we obtain (see Supplementary Materials for details) where represents the Fourier transform of the function with the variable , and the transformed function variable is .
Taking Eqs. (7) and (12) into Eq. (5), we have where and
According to the Wiener–Khinchin theorem for deterministic signals[30] (also known as the autocorrelation theorem[31]), we have
Substituting Eq. (16) into Eq. (13), we obtain
Equation (17) indicates that the energy spectral density of the intensity distribution on the object plane can be separated from , and the resolution is determined by . The image of can be reconstructed by utilizing phase retrieval algorithms[32–36]. Here, only the amplitude information of the target is interested, which can be used as a constraint to significantly improve the speed and quality of reconstruction[37].
To quantify the imaging system, the relationship between the field of view (FOV), the resolution, and the spatial random phase modulator is analyzed.
The space translation invariance of the system in space (also known as the memory effect[38–40]) is required in the lensless Wiener–Khinchin telescope; therefore, its FOV is limited by the memory effect range of the imaging system. Since the target of a telescope is very small compared with the imaging distance, the memory effect in its FOV is satisfied. The corresponding normalized second-order correlation function of light fields between different incident angles without transverse translation is (see Supplementary Materials for details) where is the variation of the incident angle. According to Eq. (18), the FOV of the lensless Wiener–Khinchin telescope is proportional to .
In addition, Eq. (17) leads to a limitation of the FOV of the lensless Wiener–Khinchin telescope, with denoting the CCD detector size. This equation indicates that the FOV is also limited by the CCD detector size. In order to obtain a large FOV, the CCD detector size of the lensless Wiener–Khinchin telescope is required to be much larger than in Eq. (18).
Equation (15) indicates that the resolution not only depends on the aperture of the spatial random phase modulator, but also the statistical properties of it. According to the convolution operation in , we discuss two simple cases below, where the resolution is mainly limited by the aperture and the statistical properties of the spatial random phase modulator, respectively.
Case 1: Resolution is mainly limited by the aperture.
When the full width at half-maximum (FWHM) of is much smaller than the FWHM of , we have
For a circle aperture of the spatial random phase modulator, , and this leads to
In this case, the resolution of the lensless Wiener–Khinchin telescope is proportional to .
Case 2: Resolution is mainly limited by the statistical properties.
When the FWHM of is much larger than the FWHM of , with the first-order approximation. In this case, the resolution is proportional to .
According to the analysis of the above two cases, Case 1 requires , namely , while Case 2 requires .
For digital images, the reconstruction is also affected by the pixel size of the CCD detector. Due to Eq. (16), the pixel size of the CCD detector is required by where denotes a split number for discrimination of the resolution. For Case 1, according to Eq. (20), the FWHM of is proportional to , and taking this result into Eq. (22), the pixel size of the CCD detector is required to be smaller than . Similarly, for Case 2, the pixel size of the CCD detector is required to be smaller than with in a telescope scheme.
The experimental setup is shown in Fig. 2. An object is illuminated by a xenon lamp. The reflected light is filtered by a narrow-band filter and modulated by a spatial random phase modulator with a height standard deviation , a transverse correlation length , and the refractive index , and then it is relayed by a lens, which has a 10× magnification, 0.25 numerical aperture, 195 mm conjugated distance, and 161 mm focus length, onto a CCD detector (APGCCD) with a pixel size , which records the magnified intensity distribution. Usually, the width of the correlation of the intensity distribution is larger than two times the pixel size of the CCD. The lens is only used to amplify the intensity distribution to match the pixel size of the CCD detector and is not necessary in some conditions.
Figure 2.Experimental setup of the lensless Wiener–Khinchin telescope.
In order to analyze the resolution of the system, a double slit [shown in Fig. 3(a)] is selected. Since the image is obtained from the second-order spatial autocorrelation of thermal light, the temporal coherence is not strictly required. But, the temporal coherence of the light field still affects the contrast of the spatial fluctuating pseudo-thermal light due to the dispersion of the spatial random phase modulator. The reflected light from the object is filtered by a narrow-band filter, whose central wavelength is either 532 or 550 nm, and its bandwidth varies among 3, 10, 25, and 50 nm, when , , and . The results with the same phase retrieval algorithm[34] are shown in Fig. 3. The experimental results show that the situation is better for narrow-band light. In subsequent experiments, a narrow-band filter with center wavelength and bandwidth is selected.
Figure 3.Experimental results with different narrow-band filters. (a) A photograph of the double slit, where a yellow scale bar is inserted in the lower right corner. Reconstructed images with different narrow-band filters: (b) , ; (c) , ; (d) , ; (e) , ; (f) , .
To verify Eq. (21) in the experiment, the aperture size is changed. Images with five different values of apertures , 4.5, 5, 6, and 8 mm are obtained, respectively, while and are selected approximately in accordance with Case 1 [see Figs. 4(a)–4(e)]. According to Eq. (20), the theoretical resolutions with different apertures are shown in Fig. 4(f), where FWHMs for , 4.5, 5, 6, and 8 mm are 150, 134, 121, 100, and , respectively. Figure 4(g) shows a comparison of theoretical and experimental resolutions at , where the red dash line denotes a cross-section of the experimental result of the double slit in Fig. 4(c). The experimental results show that the double slit can be distinguished at , which agrees well with the theoretical results.
Figure 4.Resolution at different apertures of the spatial random phase modulator. Reconstructed images with different apertures: (a) , (b) , (c) , (d) , (e) . (f) The theoretical resolutions. (g) A comparison between theoretical and experimental resolutions at , and the vertical red bar denotes a cross-section of the experimental result of the double slit in Fig. 4(c).
In Case 2, the resolution is mainly affected by the statistical properties of the spatial random phase modulator, which leads to a limitation of based on Eq. (22). Five different values of (4, 6, 8, 10, and 12 mm) are selected, and the reconstructed images are shown in Figs. 5(a)–5(e), while and . The corresponding theoretical resolutions are shown in Fig. 5(f), where FWHMs for , 6, 8, 10, and 12 mm are 156, 106, 80, 65, and , respectively. Figure 5(g) shows a comparison of theoretical and experimental resolutions at , where the red dash line denotes a cross-section of the experimental result of the double slit in Fig. 5(c). The results show that the double slit can be distinguished at .
Figure 5.Resolution at different . Reconstructed images with different : (a) , (b) , (c) , (d) , (e) . (f) The theoretical resolutions. (g) A comparison between the theoretical and experimental resolutions at , and the vertical red bar denotes a cross-section of the experimental result of the double slit in Fig. 5(c).
To further verify the imaging capability of the lensless Wiener–Khinchin telescope, two targets, a letter and a panda toy, are imaged, respectively. The illumination is also a xenon lamp. Different system parameters are selected for the two targets at . For the ‘’, , , and for the ‘panda’, , . The reconstructed images of both are shown in Fig. 6.
Figure 6.Imaging of a letter and a panda toy. (a) and (b) are photographs, where a yellow scale bar is inserted in the lower right corner, respectively. (c) and (d) are reconstructed images, respectively.
For astronomical observations, the distance is nearly infinitely far away, which means , so the resolution in Eq. (15) is approximated to
An object ‘GI’ is placed on the focal plane of an optical lens before the spatial random phase modulator to experimentally simulate the target placed infinitely far away. The image can be well reconstructed, as shown in Fig. 7. Imaging for both far and equivalently infinite far away demonstrated in Figs. 6 and 7 proves the feasibility of the lensless Wiener–Khinchin telescope in astronomical observations.
Figure 7.Imaging an object placed equivalently infinite far away. (a) A photograph of the target, where a yellow scale bar is inserted in the lower right corner. (b) Reconstructed image.
In conclusion, we present a novel theoretical framework for imaging schemes through random media and propose the lensless Wiener–Khinchin telescope based on second-order spatial autocorrelation of thermal light. The attempt to extract spatial information of an object from high-order correlation of light fields can be traced back to the famous Hanbury Brown and Twiss (HBT) experiment in 1956[41,42], which is based on the second-order autocorrelation of light fields, and GI in 1995, which is based on second-order mutual correlation of light fields between the reference and test arms[43]. The HBT experiment and many of the early works of GI[44,45] perform ensemble statistics of the temporal fluctuating light field in the time domain, which requires that the temporal resolution of the detector is close to or less than the coherence time of the light field[46]. In contrast, by modulating true thermal light, such as sunlight, into a spatially fluctuating pseudo-thermal light field through a spatial random phase modulator[10], the lensless Wiener–Khinchin telescope based on second-order spatial autocorrelation of thermal light calculates the ensemble statistics of the spatially fluctuating pseudo-thermal light field in the spatial domain; therefore, the detection of the temporal intensity fluctuation is not required.
On the other hand, from the viewpoint of the intensity autocorrelation, single-shot imaging through scattering layers and around corners via speckle correlations presented by Katz et al.[17] did not consider the diffraction effects of light through random phase modulation; therefore, the resolution of the imaging system can hardly be quantitatively calculated. By analyzing the second-order correlation of light fields, the resolution is derived and experimentally verified in the lensless Wiener–Khinchin telescope. The quantitative description of the imaging quality allows for such imaging systems to not only be demonstrated, but also be designed in practical applications.
Compared with lensless compressive sensing imaging[12,47,48] and lensless GI[46,49,50], neither a measurement matrix nor a calibration process is required. Thus, the lensless Wiener–Khinchin telescope has conspicuous advantages in applications such as X-ray astronomical observations, where the measurement matrix or the calibration for an unknown imaging distance is difficult and less accurate. The cancellation of calibration also results in lower requirements in system stability. Moreover, considering the scattering media or the randomly inhomogeneous media as a spatial random phase modulator, the lensless Wiener–Khinchin telescope may also open a door to quantitatively describe imaging through scattering media or randomly inhomogeneous media[5,7–12,14–20].