• Acta Optica Sinica
  • Vol. 38, Issue 2, 0211001 (2018)
Yuqing Hou, Haowen Hu, Fengjun Zhao*, Xuelei He, Huangjian Yi, and Xiaowei He
Author Affiliations
  • School of Information and Technology, Northwest University, Xi'an, Shaanxi 710127, China
  • show less
    DOI: 10.3788/AOS201838.0211001 Cite this Article Set citation alerts
    Yuqing Hou, Haowen Hu, Fengjun Zhao, Xuelei He, Huangjian Yi, Xiaowei He. Influence of Active Shape Model Segmentation Method on Optical Reconstruction[J]. Acta Optica Sinica, 2018, 38(2): 0211001 Copy Citation Text show less
    Left kidney image segmentation results obtained by different methods. (a) ASM1 method; (b) ASM2 method; (c) ASM3 method; (d) ASM4 method; (e) Snake method; (f) manual segmentation
    Fig. 1. Left kidney image segmentation results obtained by different methods. (a) ASM1 method; (b) ASM2 method; (c) ASM3 method; (d) ASM4 method; (e) Snake method; (f) manual segmentation
    Reconstruction results of the new grids obtained by different methods and the original grid. (a) ASM1 method; (b) ASM2 method; (c) ASM3 method; (d) ASM4 method; (e) Snake method; (f) original grid
    Fig. 2. Reconstruction results of the new grids obtained by different methods and the original grid. (a) ASM1 method; (b) ASM2 method; (c) ASM3 method; (d) ASM4 method; (e) Snake method; (f) original grid
    Organμaxμsxμamμsm
    Muscle0.00521.080.00681.03
    Heart0.00831.010.01040.99
    Lung0.01331.970.02031.95
    Liver0.03290.700.01760.65
    Kidney0.06602.250.03802.02
    Stomach0.01141.740.00701.36
    Table 1. Optical parameters of digital mouse modelmm-1
    MethodDice coefficientHausdorff distance /mm
    ASM10.800.98
    ASM20.860.52
    ASM30.890.41
    ASM40.900.30
    Snake0.840.78
    Table 2. Accuracy of segmentation based on active shape models and Snake model
    Methoddf /mmReconstructed density /(nW·mm-3)Number of nodesNumber of tetrahedrons
    ASM13.852.86×10-2387818852
    ASM22.333.19×10-2392619099
    ASM31.963.18×10-2385118636
    ASM41.753.03×10-2391719011
    Snake2.922.97×10-2387218767
    Original1.703.13×10-2382318504
    Table 3. Reconstruction results
    Yuqing Hou, Haowen Hu, Fengjun Zhao, Xuelei He, Huangjian Yi, Xiaowei He. Influence of Active Shape Model Segmentation Method on Optical Reconstruction[J]. Acta Optica Sinica, 2018, 38(2): 0211001
    Download Citation