• Laser & Optoelectronics Progress
  • Vol. 54, Issue 9, 91101 (2017)
Lü Ze1、2、*, Chen Youhua1、2, Xue Peng1、2, Wang Zhibin1、2, and Chen Yuanyuan1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/lop54.091101 Cite this Article Set citation alerts
    Lü Ze, Chen Youhua, Xue Peng, Wang Zhibin, Chen Yuanyuan. Image Distortion Analysis and Correction Study of AOTF Camera Imaging Process[J]. Laser & Optoelectronics Progress, 2017, 54(9): 91101 Copy Citation Text show less
    References

    [1] Liu Jifan, Ma Yanhua, Zhang Lei, et al. New hyperspectral imaging system based on AOTF[J]. Infrared and Laser Engineering, 2013, 42(11): 3065-3069.

    [2] Wang J Y, He Z P, Shu R. Design and applications of space-borne imaging spectrometer based on acousto-optic tunable filter (AOTF)[J]. SPIE, 2010, 7857: 78570N.

    [3] Jiang Yi, Zeng Libo, Wu Qiongshui, et al. Microscopic spectral imaging based on an acousto-optic tunable filter[J]. Optical Technique, 2005, 31(2): 193-195.

    [4] Machikhin A, Pozhar V, Batshev V. Acousto-optic video spectrometer module for medical endoscopic studies[J]. Journal of Optical Technology, 2013, 80(7): 439-443.

    [5] Gao Qiang, Zhang Chunguang, Wang Hao, et al. Hyperspectral imaging of human gastric parietal cells based on narrowband AOTF[J]. Laser & Optoelectronics Progress, 2015, 52(12): 122205.

    [6] Zhou Qianfei, Liu Jinghong, Li Gang. Error analysis of geometric distortion correction of oblique images for array CCD aerial cameras[J]. Chinese Journal of Scientific Instrument, 2014, 35(s1): 1-8.

    [7] Haneishi H, Yagihashi Y, Miyake Y. A new method for distortion correction of electronic endoscope images[J]. IEEE Transactions on Medical Imaging, 1995, 14(3): 548-555.

    [8] Liu Hang, Yu Daoyin, Du Ji, et al. Distortion correction of the wide-angle optical system with digital technology[J]. Acta Optica Sinica, 1998, 18(8): 1108-1112.

    [9] Tsai R Y. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses[J]. IEEE Journal of Robotics and Automation, 1987, 3(4): 323-344.

    [10] Pozhar V, Machihin A. Image aberrations caused by light diffraction via ultrasonic waves in uniaxial crystals[J]. Applied Optics, 2012, 51(19): 4513-4519.

    [11] Hua Xijun, Xia Lechun, Gao Fuxue, et al. Camera calibration for model visualization with tangential distortion[J]. Journal of Engineering Graphics, 2009, 30(3): 121-125.

    [12] Fang Suping, Xia Xiaohua, Xiao Yan, et al. Lens Distortion calibration method for linear array cameras[J]. Journal of Xi′an Jiaotong University, 2013, 47(1): 11-14.

    [13] Machikhin A, Pozhar V, Batshev V. Double-AOTF-based aberration-free spectral imaging endoscopic system for biomedical applications[J]. Journal of Innovative Optical Health Sciences, 2015, 8(3): 1541009.

    [14] Machikhin A S, Pozhar V E. Image transformation caused by wide-angle acousto-optic interaction[J]. Quantum Electronics, 2010, 40(9): 837-841.

    [15] Lin J M, Xing M L, Sha D G, et al. Distortion measurement of CCD imaging system with short focal length and large-field objective[J]. Optics and Lasers in Engineering, 2005, 43(10): 1137-1144.

    Lü Ze, Chen Youhua, Xue Peng, Wang Zhibin, Chen Yuanyuan. Image Distortion Analysis and Correction Study of AOTF Camera Imaging Process[J]. Laser & Optoelectronics Progress, 2017, 54(9): 91101
    Download Citation