• Optics and Precision Engineering
  • Vol. 18, Issue 6, 1333 (2010)
WANG Yong-cheng1,2,*, DANG Yuan-yuan3, XU Shu-yan1, and SONG Ke-fei1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: Cite this Article
    WANG Yong-cheng, DANG Yuan-yuan, XU Shu-yan, SONG Ke-fei. Application of tolerance analysis to temperature measurement circuit of space camera[J]. Optics and Precision Engineering, 2010, 18(6): 1333 Copy Citation Text show less

    Abstract

    In order to improve the temperature measurement accuracy of space cameras,the tolerance analysis is applied to temperature measurement circuits.The principle of a temperature measurement circuit is studied and a variety of influencing factors of temperature measurement accuracy are discussed.Several kinds of tolerance analysis methods are described, and their respective advantages and disadvantages are compared.Then the worst-case analysis method is chosen to analyze the tolerance of the temperature measurement circuit.Finally, a novel method for improving temperature measurement accuracy is proposed according to the analysis results.After validating proposed method,it is shown that the measurement accuracy of the improved temperature measurement circuit is ±0.3℃, 30 times higher than that of the original method,which can meet the requirements of temperature measurement in -14 ℃-+50 ℃.
    WANG Yong-cheng, DANG Yuan-yuan, XU Shu-yan, SONG Ke-fei. Application of tolerance analysis to temperature measurement circuit of space camera[J]. Optics and Precision Engineering, 2010, 18(6): 1333
    Download Citation