• Acta Optica Sinica
  • Vol. 38, Issue 2, 0230001 (2018)
Jinguang Lü1, Jingqiu Liang1、*, Zhongzhu Liang1, and Yuxin Qin1、2
Author Affiliations
  • 1 State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China
  • 2 University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/AOS201838.0230001 Cite this Article Set citation alerts
    Jinguang Lü, Jingqiu Liang, Zhongzhu Liang, Yuxin Qin. Wavefront Aberration Analysis and Spectrum Correction of Microminiature Fourier Transform Spectrometer[J]. Acta Optica Sinica, 2018, 38(2): 0230001 Copy Citation Text show less
    References

    [1] Weng S F[M]. Fourier transform infrared spectrometer, 34-56(2005).

    [2] Griffiths P R, de Haseth J A. Fourier transform infrared spectrometry[M]. New Jersey: John Wiley and Sons Publication, 19-41(2007).

    [3] Manzardo O. Micro-sized Fourier spectrometers[D]. Neuchatel: University of Neuchatel Institute of Microtechnique, 29-54(2002).

    [4] Manuilskiy A, Andersson H, Tungstrom G et al. Compact multi channel optical Fourier spectrometer[C]. SPIE, 6395, 639504(2006).

    [5] Liang J Q, Liang Z Z, Lü J G et al. Micro spatial modulation Fourier transform infrared spectrometer[J]. Chinese Optics, 8, 277-296(2015).

    [6] Fu J G, Liang J Q, Liang Z Z. Analysis and design for the optical system of a static infrared Fourier transform spectrometer[J]. Acta Optica Sinica, 32, 0222006(2012).

    [7] Lü J G, Liang J Q, Liang Z Z et al. Analysis and restraint of alignment error by stepped micro-mirror[J]. Acta Optica Sinica, 36, 0330003(2016).

    [8] Feng C, Wang B, Liang Z Z et al. Miniaturization of step mirrors in a static Fourier transform spectrometer: Theory and simulation[J]. Journal of the Optical Society of America B, 28, 128-133(2011). http://www.opticsinfobase.org/abstract.cfm?URI=josab-28-1-128

    [9] Lü J G, Liang J Q, Liang Z Z et al. Optical field analysis and diffraction restraint of microminiature Fourier transform spectrometer[J]. Acta Optica Sinica, 36, 1130002(2016).

    [10] Lü N G[M]. Fourier optics, 89-90(2007).

    [11] Feng C, Liang J Q, Liang Z Z. Spectrum constructing with nonuniform sample using least-squares approximation by cosine polynomials[J]. Applied Optics, 50, 6377-6383(2011). http://europepmc.org/abstract/MED/22192989

    [12] Feng Y T, Sun J, Li Y et al. Broad-band spatial heterodyne interferometric spectrometer[J]. Optics and Precision Engineering, 23, 48-55(2015).

    [13] Mu T K, Zhang C M, Li Q W et al. The polarization difference interference imaging spectrometer - I. concept, principle, and operation[J]. Acta Physica Sinica, 63, 110704(2014).

    Jinguang Lü, Jingqiu Liang, Zhongzhu Liang, Yuxin Qin. Wavefront Aberration Analysis and Spectrum Correction of Microminiature Fourier Transform Spectrometer[J]. Acta Optica Sinica, 2018, 38(2): 0230001
    Download Citation