  • 1School of Precision Instrument and Opto-Electronics Engineering, Key Laboratory of Micro Opto-electro Mechanical System Technology, Institute of Optical Fiber Sensing of Tianjin University, Tianjin Optical Fiber Sensing Engineering Center, Key Laboratory of Opto-Electronics Information Technology (Tianjin University), Ministry of Education, Tianjin 300072, China
  • 2School of Computer and Information Engineering, Tianjin Chengjian University, Tianjin 300384, China
  • show less
    DOI: 10.3788/COL201715.040601 Cite this Article Set citation alerts
    Huijia Yang, Junfeng Jiang, Shuang Wang, Yuheng Pan, Xuezhi Zhang, Tiegen Liu. Temperature-insensitive optical Fabry–Perot flow measurement system with partial bend angle[J]. Chinese Optics Letters, 2017, 15(4): 040601 Copy Citation Text show less

    Abstract

    A flow measurement system consisting of an optical fiber Fabry–Perot (F-P) sensor and an elbow tube is proposed and demonstrated to realize flow measurements and eliminate thermal disturbance. Two F-P sensors are symmetrically mounted on the inner-wall surface of the elbow of 90° in order to eliminate the effect of thermal disturbance to the flow measurement accuracy. Experimental results show that the absolute phase difference is the square root of the fluid flow. It is consistent with the theoretical analysis, which proves that the flow measurement method can measure flow and eliminate the influence of thermal disturbance simultaneously.
    Q=πD24RD·ΔP(m,T)ρ(T),(1)

    View in Article

    I(d,l)=(1+μ2)1/4exp[(xΔk)24σ(1+μ2)]cos(Ψ(d,l)),(2)

    View in Article

    Ψ(x)=μΔk2x24σ(1+μ2)+xk0αk02d+0.5arctanμ.(3)

    View in Article

    ψ(s)=ψP(s)+ψT(s).(4)

    View in Article

    ΔP(m,T)=Ph(m,T)Pl(m,T)ξhψh(s)ξlψl(s)=ξhψPh(s)ξlψPl(s)+ξhψTh(s)ξlψTl(s).(5)

    View in Article

    Q=πD24(Rρ(T)D)1/2dPhase1/2ξp1/2.(6)

    View in Article

    Q=1.89(1.06dPhase+0.94)121.36.(7)