• Laser & Optoelectronics Progress
  • Vol. 60, Issue 10, 1015002 (2023)
Qinghua Wu1、2、*, Jiefeng Qiu1、2、**, Zhiang Li1、2, Jiacheng Liu1、2, and Biao Wang1、2
Author Affiliations
  • 1School of Mechanical Engineering, Hubei University of Technology, Wuhan 430068, Hubei, China
  • 2Hubei Provincial Key Laboratory of Modern Manufacturing Quality Engineering, Wuhan 430068, Hubei, China
  • show less
    DOI: 10.3788/LOP220852 Cite this Article Set citation alerts
    Qinghua Wu, Jiefeng Qiu, Zhiang Li, Jiacheng Liu, Biao Wang. Hand-Eye Calibration Method of Line Structured Light Vision Sensor Robot Based on Planar Target[J]. Laser & Optoelectronics Progress, 2023, 60(10): 1015002 Copy Citation Text show less

    Abstract

    To determine the pose relationship between a linear structured light vision sensor and the flange center of an industrial robot, a planar target with only a single circle and its calibration method are designed. The robot's attitude is adjusted such that the laser line passes through the center of the solid circle on the plane target. Through image processing, the pixel coordinates of the center are obtained. After conversion, the coordinates of the center in the sensor coordinate system are obtained. The attitude is adjusted many times, yielding multiple sets of images and the center coordinates of multiple groups of sensors in the sensor coordinate system. The hand-eye matrix is directly solved using the least-squares method based on the corresponding robot pose relationship. The experimental results show that the standard deviation of the three-dimensional coordinates obtained by the proposed method is reduced from 0.3893 mm to 0.2145 mm compared with the hand-eye calibration method using the standard ball as the target, and the root mean square error is effectively reduced with different distances of the same target as the measurement object. This method improves calibration accuracy, does not require expensive targets, and is suitable for field calibration.
    suv1T=ACxCyCzC1T
    xCyCzC1T=HCLxLyLzL1T
    uv1T=1sACHCLxLyLzL1T
    uv1T=1sACHCLxL0zL1T
    xL0zL1T=HLTxTyTzT1T
    xTyTzT1T=HTBxByBzB1T
    xL0zL1T=HLTHTBxByBzB1T
    uv1T=1sACHCLHLTHTBxByBzB1T
    xByBzB1T=AiHLT-1xLi0zLi1T
    xByBzB1T=A1HLT-1xL10zL11TxByBzB1T=A2HLT-1xL20zL21TxByBzB1T=AnHLT-1xLn0zLn1T
    A1HLT-1xL10zL11T=AiHLT-1xLi0zLi1T,  i=2,3,,n
    Ai=RiTi01HLT-1=r1r2r3t0001
    RixL1-RixLir1+RiyL1-RiyLir2+RizL1-RizLir3+R1-Rit=Ti-T1
    R1x1-R2x2R1y1-R2y2R1z1-R2z2R1-R2R1x1-R3x3R1y1-R3y3R1z1-R3z3R1-R3R1x1-RnxnR1y1-RnynR1z1-RnznR1-Rnr1r2r3t=T2-T1T3-T1Tn-T1
    HLT=    0.9973-0.0275-0.0296 -8.2886-0.0668-0.1147    0.0038-34.6238    0.0283    0.9930    0.9996  299.6681    0    0    0       1
    K=inxi-x¯2+yi-y¯2+zi-z¯2/n-1
    Qinghua Wu, Jiefeng Qiu, Zhiang Li, Jiacheng Liu, Biao Wang. Hand-Eye Calibration Method of Line Structured Light Vision Sensor Robot Based on Planar Target[J]. Laser & Optoelectronics Progress, 2023, 60(10): 1015002
    Download Citation