• Acta Optica Sinica
  • Vol. 36, Issue 9, 911003 (2016)
Lü Hang1、*, Liao Ningfang1, Wu Wenmin1, Cao Weiliang1, Wang Jiajia1, and Cheng Haobo2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201636.0911003 Cite this Article Set citation alerts
    Lü Hang, Liao Ningfang, Wu Wenmin, Cao Weiliang, Wang Jiajia, Cheng Haobo. Zero-Order Drift of Interferograms in Ultraviolet Imaging Spectrometer[J]. Acta Optica Sinica, 2016, 36(9): 911003 Copy Citation Text show less
    References

    [1] Jin Yangming, Wang Yan, Zhao Zhicheng, et al. Analysis and comparison of signal-to-noise ratio of spatially modulated interference and diffraction grating imaging spectrometers[J]. Acta Optica Sinica, 2015, 35(9): 0911001.

    [2] Chen J, Zhu Y, Liu B, et al. Experimental study of Fourier transform spectrometer based on MEMS micro-mirror[J]. Chinese Optics Letters, 2013, 11(5): 053003.

    [3] Kang Li, Huang Min, Nie Yunfeng, et al. Spectral inversion modeling and manufacture tolerance analysis of a solid Mach-Zehnder imaging spectrometer[J]. Acta Optica Sinica, 2014, 34(3): 0311002.

    [4] Horton R. HEIFTS-design, modeling and recent experimental results[C]. Optical Society of America Trends in Optics and Photonics, Coeur d’Alene, 2001: FWC3.

    [5] Xue Qingsheng. Optical design of spaced-based broadband limb ozone profile sounder[J]. Acta Optica Sinica, 2015, 35(8): 0822002.

    [6] Zhu Yang, Zhang Xin, Wu Yanxiong, et al. Optical design and stray light analysis for ultraviolet board width off-axis four mirrors optical system[J]. Chinese J Lasers, 2015, 42(2): 0216001.

    [7] Liu Yang, Liao Ningfang, Bai Tingzhu, et al. Study of the structure of large aperture ultraviolet Fourier transform imaging spectrometer[J]. Acta Optica Sinica, 2014, 34(3): 0330001.

    [8] Liao Ningfang, Lü Hang, Liu Yang, et al. Broadband close shot ultraviolet imaging spectrum device: CN103940514A[P]. 2014-07-23.

    [9] Lü Jinguang, Liang Jingqiu, Liang Zhongzhu, et al. Study on interferogram-spectrum modulation by the rotation of compensation plate in static Fourier transform spectrometer[J]. Acta Optica Sinica, 2015, 35(11): 1130001.

    [10] Lü Hang, Liao Ningfang, Wu Wenmin, et al. Interferogram baseline correction method based on self-adaptive differential filtering[J]. Acta Optica Sinica, 2015, 35(10): 1030002.

    [11] Georgiev G T, Butler J J. Long-term calibration monitoring of spectralon diffusers BRDF in the air-ultraviolet[J]. Applied Optics, 2007, 46(32): 7892-7899.

    CLP Journals

    [1] Jin Yunfei, Wang Houmao, Wang Yongmei. On-Orbit Monitoring Test and Analysis of Ultraviolet Radiation of Spacecraft Engine Plumes[J]. Laser & Optoelectronics Progress, 2018, 55(7): 72802

    Lü Hang, Liao Ningfang, Wu Wenmin, Cao Weiliang, Wang Jiajia, Cheng Haobo. Zero-Order Drift of Interferograms in Ultraviolet Imaging Spectrometer[J]. Acta Optica Sinica, 2016, 36(9): 911003
    Download Citation