• Infrared and Laser Engineering
  • Vol. 48, Issue 5, 517001 (2019)
Wang Jianbo*, Qian Jin, Yin Cong, Lu Zuliang, Huang Lu, and Yang Yan
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/irla201948.0517001 Cite this Article
    Wang Jianbo, Qian Jin, Yin Cong, Lu Zuliang, Huang Lu, Yang Yan. Precise capacitance measurement by laser locking Fabry-Perot interferometer[J]. Infrared and Laser Engineering, 2019, 48(5): 517001 Copy Citation Text show less
    References

    [1] Thompson A M, Lampard D G. A new theorem in electrostatics and its application to calculable standards of capacitance [J]. Nature, 1956, 177(455): 888.

    [2] Thompson A M. The precise measurement of small capacitances [J]. IRE Trans Instrum, 1958, 7(3): 245-253.

    [3] Lu Z L, Huang L, Yang Y, et al. Research for reproducing SI unit of capacitance by the calculable capacitor with a movable guard rod [J]. Acta Metrologica Sinica, 2014, 35(6): 521-527.

    [4] Thompson A M. The cylindrical cross-capacitor as a calculable standard [C]//IEEE Transactions on Instrumentation and Meansurement, 1959, 106(27): 307-310.

    [5] Lampard D G, Cutkosky R D. Some results on the cross-capacitances per unit length of cylindrical three-terminal capacitors with thin dielectric films on their electrodes [C]// Proc IEE - Part C: Monographs, 1960, 107(11): 112-119.

    [6] Makow D, Campbell J B. Circular four electrode capacitors for capacitance standards [J]. Metrologia, 1972, 8(4): 148-155.

    [7] Rayner G H. NPL calculable capacitor[J]. IEEE Transactions on Instrumentation and Meansurement, 1972, 21(4): 361-365.

    [8] Cutkosky R D. New NBS measurements of the absolute farad and ohm [C]//IEEE Transactions on Instrumentation and Meansurement, 1974, 23(4): 305-309.

    [9] Cross Capacitor Group of National Institute of Metrology. A calculable cross capacitor and absolute measurement of electrical impedance [J]. Acta Metrologica Sinica, 1980(1): 16-26.

    [10] Jones K, Corney A C. The PEL calculable capacitor[J]. Metrologia, 1987, 24(1): 1-11.

    [11] Small G W. Refinements to the use of the NML calculable capacitor in relation to SI ohm determinations [C]//Conf Precis Electromagn Meas (CPEM), 1996: 8-9.

    [12] Trapon G, Thevenot O, Lacueille J C, et al. Realization of the farad at BNM-LCIE [C]//Conf Precis Electromagn Meas(CPEM), 1998: 448-449.

    [13] Small G W, Fiander J R. Design of a calculable cross-capacitor [C]//Conf Precis Electromagn Meas (CPEM), 2004: 485-486.

    [14] Thevenot O, Lahousse L, Consejo C, et al. Towards a determination of RK in terms of the new LNE calculable cross capacitor [C]//Proc Simposio de Metrologia, Santiago de Querétaro, 2008, 1142: 1-7.

    [15] Small G W, Fiander J R. Fabrication and measurement of the main electrodes of the NMIA-BIPM calculable cross capacitors [J]. IEEE Transactions on Instrumentation and Meansurement, 2011, 60(7): 2489-2494.

    [16] Yicheng W, Pratt J, Rae Duk L, et al. Main electrodes alignment for NIST calculable capacitor [C]//Conf Precis Electromagn Meas(CPEM), 2012: 392-393.

    [17] Lu Z, Huang L, Yang Y, et al. An initial reproduction of SI capacitance unit from a new calculable capacitor at NIM[J].IEEE Transactions on Instrumentation and Meansurement, 2015, 64(6): 1496-1502.

    [18] Wang J, Qian J, Liu Z, et al. Displacement determination of the guard electrode for the new calculable capacitor at NIM [C]//IEEE Transactions on Instrumentation and Measurement, 2016, 65(11): 2569-2577.

    [19] Yicheng W, Rae Duk L, Liang L, et al. Next-generation calculable capacitor using a tunable-laser interferometer [C]// Conf Precis Electromagn Meas (CPEM), 2008: 686-687.

    [20] Lawall J R. Fabry-Perot metrology for displacements up to 50 mm [J]. J Opt Soc Am A, 2005, 22(12): 2786-2798.

    [21] Durand M, Lawall J, Wang Y. Fabry-Perot displacement interferometry for next-generation calculable capacitor[J].IEEE Transactions on Instrumentation and Meansurement, 2011, 60(7): 2673-2677.

    [22] Wang Y, Yu Y, Pratt J R. Evaluation of a continuously variable calculable capacitor[J]. IEEE Transactions on Instrumentation and Meansurement, 2017, 66(6): 1503-1510.

    [23] Fletcher N, Goebel R, Robertsson L, et al. Progress towards a determination of RK at the BIPM [C]//Conf Precis Electromagn Meas(CPEM), 2012: 252-253.

    [24] Lampard D G. A new theorem in electrostatics with applications to calculable standards of capacitance [J]. IEE -Part C: Monographs, 1957, 104(6): 271-280.

    [25] Wang J B, Qian J, Liu Z Y, et al. Methode of phase correction of displacement measurement using Fabry-Perot interferometer in calculable capacitor [J]. Acta Physica Sinica, 2016, 65(11): 110601.

    Wang Jianbo, Qian Jin, Yin Cong, Lu Zuliang, Huang Lu, Yang Yan. Precise capacitance measurement by laser locking Fabry-Perot interferometer[J]. Infrared and Laser Engineering, 2019, 48(5): 517001
    Download Citation