• Journal of Innovative Optical Health Sciences
  • Vol. 7, Issue 6, 1450035 (2014)
Lihui Yin, Xuebo Zhang, Xiaodong Li, and Shaohong Jin*
Author Affiliations
  • National Institutes for Food and Drug Control No. 2 Tiantan Xili, Beijing, P. R. China
  • show less
    DOI: 10.1142/s1793545814500357 Cite this Article
    Lihui Yin, Xuebo Zhang, Xiaodong Li, Shaohong Jin. Development and implementation of incident response near-infrared models for analyzing contaminated medicines containing diethylene glycol solvent[J]. Journal of Innovative Optical Health Sciences, 2014, 7(6): 1450035 Copy Citation Text show less
    References

    [1] Y. Juillet, A. P. Vlasto, "Counterfeiting of medicinal drugs: Issues and threats," Fund. Clin. Pharmacol. 19(6), 621–624 (2005).

    [2] World Health Organization (WHO), "Combating counterfeit drugs: A concept paper for effective international cooperation," Concept paper, WHO, Rome, 27 January 2006, Available at www.who.int/ medicines/counterfeit conference/en/index.html.

    [3] International Medical Products Anti-Counterfeiting Taskforce — IMPACT, Available at http://www. who.int/impact/en/.

    [4] Y. C. Feng, C. Q. Hu, "The construction and feasibility study of near infrared system for fake and counterfeit drug identification," Chin. Pharm. Aff. 18(4), 250–252 (2004).

    [5] C. Q. Hu, W. B. Zou, W. S. HU, X. K. Ma, M. Z. Yang, S. L. Zhou, J. F. Sheng, Y. Li, S. H. Cheng, J. Xue, "Establishment of a fast chemical identifi- cation system for screening of counterfeit drugs of macrolide antibiotics," J. Pharm. Biomed. Anal. 40, 68–74 (2006).

    [6] FDA Advises Manufacturers to Test Glycerin for Possible Contamination, Available at http://www. fda.gov/NewsEvents/Newsroom/PressAnnouncements/ 2007/ucm108909.htm.

    [7] Bangladesh medicine `was toxic', Available at http://news.bbc.co.uk/2/hi/south asia/817287

    [8] stm. 8. G. Reich, "Near-infrared spectroscopy and imaging: Basic principles and pharmaceutical applications," Adv. Drug Deliver. Rev. 57(8), 1109–1143 (2005).

    [9] R. G. Brereton, "Introduction to multivariate calibration in analyticalchemistry," Analyst. 125, 2125–2154 (2000).

    [10] D. A. Burns, E. W. Ciurczak, Handbook of Near- Infrared Analysis, 3rd Edition, CRC Press, Boca Raton (2008).

    [11] A. Savitzky, M. J. Golay, "Smoothing and differentiation of data by simplified least squares procedures," Anal. Chem. 36, 1627–1639 (1964).

    [12] R. J. Barnes, M. S. Dhanoa, S. J. Lister, "Standard Normal Variate Transformation and De-trending of Near-Infrared Diffuse Reflectance Spectra," Appl. Spectrosc. 43(5), 772–777 (1989).

    [13] A. Garrido-Varo, R. Carrette, V. Fernandez-Cabanas, "Use of difference near infrared reflectance spectra to extract relevant information from the spectra of agro-food products," J. Near Infrared Spectrosc. 6, 89–95 (1998).

    [14] X. Li, S. Arzhantsev, J. F. Kauffman, J. A. Spencer, "Detection of diethylene glycol adulteration in propylene glycol — Method validation through a multiinstrument collaborative study," J. Pharm. Biomed. Anal. 54(5), 1001–1006 (2011).

    Lihui Yin, Xuebo Zhang, Xiaodong Li, Shaohong Jin. Development and implementation of incident response near-infrared models for analyzing contaminated medicines containing diethylene glycol solvent[J]. Journal of Innovative Optical Health Sciences, 2014, 7(6): 1450035
    Download Citation