[1] J E Martin, N P Fox, P J Key. A cryogenic radiometer for absolute radiometric measurements [J]. Metrologia, 1985, 21(3): 147-155.
[2] N P Fox. Trap detectors and their properties[J]. Metrologia, 1991, 28(3): 197-202.
[3] B C Johnson, C L Cromer, R D Saunders, et al.. A method of realizing spectral irradiance based on an absolute cryogenic radiometer[J]. Metrologia, 1993, 30(4): 309-315.
[4] B C Johnson, S W Brown, G P Eppeldauer, et al.. System-level calibration of a transfer radiometer used to validate EOS radiance scales[J]. International Journal of Remote Sensing, 2003, 24(2): 339-356.
[5] V Ahtee, S W Brown, T C Larason, et al.. Comparison of absolute spectral irradiance responsivity measurement techniques using wavelength-tunable lasers[J]. Appl Opt, 2007, 46(20): 4228-4236.
[6] Y J Liu, G Xu, M Ojanen, et al.. Spectral irradiance comparison using a multi-wavelength filter radiometer [J]. Metrologia, 2009, 46(S1): 81-85.
[7] S W Brown, R D Saunders, Z Li, et al.. An absolute detector-based spectral radiance source [C]. SPIE, 2010, 7807: 78070A.
[8] Yang Xiaohu, Wang Shurong, Huang Yu, et al.. Wavelength dependence of the spectral irradiance of standard lamp and bi-reflection distribution function of diffuser based on standard detectors [J]. Acta Optica Sinica, 2011, 31(6): 0612008.
[9] Zhang Chunlei, Xiang Yang. Accuracy analysis of imaging spectrometer radiometric calibration using standard detector-diffuser method [J]. Laser & Optoelectronics Progress, 2011, 48(6): 061101.
[10] B C Johnson, J B Fowler, C L Cromer. SeaWiFS Postlaunch Technical Report Series, Volume 1. The SeaWiFS Transfer Radiometer[R]. NASA/TM-1998-206892, 1998.
[12] Li Jianjun, Zheng Xiaobing, Lu Yunjun, et al.. Absolute calibration of the spectral responsivity of silicon trap detectors between 350 nm and 1064 nm [J]. Acta Physica Sinica, 2009, 58(9): 6273-6278.
[13] Zhai Wenchao, Li Jianjun, Zheng Xiaobing, et al.. Research on method of calibration sun channels of sun radiometers [J]. Acta Optica Sinica, 2012, 32(4): 0412004.
[14] Zou Peng, Zheng Xiaobing, Wu Haoyu, et al.. Development of multi-band radiance standard transfer detector [J]. Acta Optica Sinica, 2011, 31(4): 0404002.
[15] Li Zhaozhou. Studies of Highly Accurate Radiometric Calibration and Application Based on Radiance Standard Detector [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2005.
[16] Zhou Lei. Research of Detector-Based Absolute Spectral Irradiance Calibration [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2007.