• Chinese Optics Letters
  • Vol. 15, Issue 10, 101202 (2017)
Xu Yuan and Bo Wang*
Author Affiliations
  • State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
  • show less
    DOI: 10.3788/COL201715.101202 Cite this Article Set citation alerts
    Xu Yuan, Bo Wang, "Using single wavelength light to improve the synchronization accuracy of the White Rabbit system," Chin. Opt. Lett. 15, 101202 (2017) Copy Citation Text show less
    References

    [1] M. Wei, M. Wang, X. Zhang, C. Wang, F. Yang. Chin. Opt. Lett., 13, 082801(2015).

    [2] M. Füßling, I. Oya, A. Balzer, D. Berge, J. Borkowski, V. Conforti, J. Colomé, R. Lindemann, E. Lyard, D. Melkumyan, M. Punch, U. Schwanke, J. Schwarz, C. Tanci, G. Tosti, P. Wegner, R. Wischnewski, A. Weinstein. Proc. SPIE, 9913, 99133C(2016).

    [3] I. A. Getting. IEEE Spectr., 30, 36(1993).

    [4] S. Younis. Time acquisition in a wireless position determination system(2005).

    [5] L. Hanzo, L. L. Yang, E. L. Kuan, K. Yen. Single-and multi-carrier DS-CDMA: multi-user detection, space-time spreading, synchronization, standards and networking(2003).

    [6] D. Lu, X. Wang, S. Fan, J. He, Y. Zhou, Y. Liu. Chin. Opt. Lett., 13, 081102(2015).

    [7] J. Ray, K. Senior. Metrologia, 42, 215(2005).

    [8] C. Han, Y. Yang, Z. Cai. Metrologia, 48, S213(2011).

    [9] X. Li, X. Zhang, X. Ren, M. Fritsche, J. Wickert, H. Schuh. Sci. Rep., 5, 8328(2015).

    [10] (2017).

    [11] Y. Bai, B. Wang, C. Gao, J. Miao, X. Zhu, L. Wang. Chin. Opt. Lett., 13, 061201(2015).

    [12] J. Serrano, M. Cattin, E. Gousio, E. van der Bij, T. Włostowski, G. Daniluk, M. Lipiński. Proceedings of IBIC2013, THBL2(2013).

    [13] D. Beck, R. Bar, M. Kreider, C. Prados, S. Rauch, W. Terpstra, M. Zweig. Proceedings of PCaPAC2012, FRIA01(2012).

    [14] G. Gong, S. Chen, Q. Du, J. Li, Y. Liu, H. He, WEBHMULT04(2011).

    [15] M. Lipinski, T. Wlostowski, J. Serrano, P. Alvarez, J. D. G. Cobas, A. Rubini, P. Moreira. IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication Proceedings, 1(2012).

    [16] U. F. Katz. Nucl. Instrum. Methods Phys. Res. Sect. A: Acceler. Spectrom. Detect. Assoc. Equip., 567, 457(2006).

    [17] E. F. Dierikx, A. E. Wallin, T. Fordell, J. Myyry, P. Koponen, M. Merimaa, R. Smets. IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 63, 945(2016).

    [18] (2017).

    [19] P. Moreira, J. Serrano, T. Wlostowski, P. Loschmidt, G. Gaderer. International Symposium on Precision Clock Synchronization for Measurement, Control and Communication, 1(2009).

    [20] T. Wlostowski. Precise time and frequency transfer in a white rabbit network(2011).

    [21] J. Eidson, L. Kang. 2nd ISA/IEEE Sensors for Industry Conference, 2002(2002).

    [22] M. Lipiński, T. Włostowski, J. Serrano, P. Alvarez. IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication, 25(2011).

    [23] P. Moriera, P. Alvarez, J. Serrano, I. Darwezeh, T. Wlostowski. IEEE International Frequency Control Symposium, 449(2010).

    [24] (2017).

    [25] . White Rabbit calibration procedure(2015).

    [26] W. Pan. Research on the High Precision Time Measurement System for the LHAASO Project(2014).

    [27] H. Li, G. Gong, Q. Du, J. Li. IEEE Trans. Nucl. Sci., 62, 3(2015).

    CLP Journals

    [1] Xi Zhu, Bo Wang, Yichen Guo, Yibo Yuan, Romeo Gamatham, Bruce Wallace, Keith Grainge, Lijun Wang, "Robust fiber-based frequency synchronization system immune to strong temperature fluctuation," Chin. Opt. Lett. 16, 010605 (2018)

    Data from CrossRef

    [1] Y. Ye, H. Li, J. Li, G. Gong. Synchronization system with symmetric optical fiber links. Journal of Instrumentation, 15, P03001(2020).

    Xu Yuan, Bo Wang, "Using single wavelength light to improve the synchronization accuracy of the White Rabbit system," Chin. Opt. Lett. 15, 101202 (2017)
    Download Citation