    (a) Schematic diagram of IWD; (b) schematic diagram of elliptic cylindrical FOG
    Fig. 1. (a) Schematic diagram of IWD; (b) schematic diagram of elliptic cylindrical FOG
    Cylindrical coordinate system of elliptic cylindrical fiber coil
    Fig. 2. Cylindrical coordinate system of elliptic cylindrical fiber coil
    The ith CCW turn of elliptic cylindrical fiber coil
    Fig. 3. The ith CCW turn of elliptic cylindrical fiber coil
    The jth CW turn of elliptic cylindrical fiber coil
    Fig. 4. The jth CW turn of elliptic cylindrical fiber coil
    Temperature excitation of fiber coil
    Fig. 5. Temperature excitation of fiber coil
    Calculated and experimental results of cylindrical fiber coil. (a) Thermal error rate; (b) thermal error angle
    Fig. 6. Calculated and experimental results of cylindrical fiber coil. (a) Thermal error rate; (b) thermal error angle
    Calculated and experimental results of elliptic cylindrical fiber coil. (a) Thermal error rate; (b) thermal error angle
    Fig. 7. Calculated and experimental results of elliptic cylindrical fiber coil. (a) Thermal error rate; (b) thermal error angle
    Comparison of rate error between elliptic cylindrical and cylindrical fiber coils
    Fig. 8. Comparison of rate error between elliptic cylindrical and cylindrical fiber coils
    ParameterVaule
    Refractive index1.46
    Density /(kg·m-3)1200
    Thermal conductivity /(W·m-1·K-1)0.13
    Specific heat /(J·kg-1·K-1)1302
    Table 1. Physical parameters of fiber coil
    NumberFiber coilLayers of fiber coilTurns of each layerTotal effective area /m2Thermal error rate /[(°)·h-1]Optimization ratio /%
    1Cylindrical2416013.12443.027635.7
    2Elliptic cylindrical249617.41211.9478
    3Cylindrical2813513.31782.795438.8
    4Elliptic cylindrical288217.73511.7096
    5Cylindrical3211613.47712.350638.6
    6Elliptic cylindrical327117.93381.4438
    Table 2. Comparison of thermal error rate between elliptic cylindrical and cylindrical fiber coils