Phase imaging with partially coherent X-ray is analyzed in terms of the optical transfer function (OTF). Differential phase-contrast imaging and direct phase-contrast imaging are discussed, and the proper experiment parameters with good image contrast and resolution are obtained. The phase restoration using image processing method, such as image fusion is discussed. The process of phase imaging and phase restoration is simulated, and different methods of phase restoration are compared.