• Laser & Optoelectronics Progress
  • Vol. 50, Issue 4, 41201 (2013)
Wang Xiaofeng*, Shen Hua, Li Jianxin, Zhu Rihong, Huang Ya, and Rong Sihai
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/lop50.041201 Cite this Article Set citation alerts
    Wang Xiaofeng, Shen Hua, Li Jianxin, Zhu Rihong, Huang Ya, Rong Sihai. Method for Calibrating the Spatial Coordinate Coherence of Shadowgraph-Taking Camera Stations at Long Distance with PSD[J]. Laser & Optoelectronics Progress, 2013, 50(4): 41201 Copy Citation Text show less

    Abstract

    The main method of the attitude measurement is to get series of graphs for analyzing the changing attitude of the projectile by utilizing multiple shadowgraph-taking camera stations. However, the premise of accurate results is that feature points on graphs must match their spatial coordinates in a certain spatial coordinate. Aiming at this problem, we propose a method of calibrating the spatial coordinate coherence for the long distance and multiple shadowgraph-taking camera stations with position sensitive detector (PSD), and analyze the measurement accuracy and repeatability of this method. A system is developed to do some regular experiments. According to the results, the accuracy of this calibration method is superior to 0.1 mm.
    Wang Xiaofeng, Shen Hua, Li Jianxin, Zhu Rihong, Huang Ya, Rong Sihai. Method for Calibrating the Spatial Coordinate Coherence of Shadowgraph-Taking Camera Stations at Long Distance with PSD[J]. Laser & Optoelectronics Progress, 2013, 50(4): 41201
    Download Citation