• Acta Optica Sinica
  • Vol. 33, Issue 9, 922002 (2013)
Chen Yang1、2、* and Wang Yueming1、3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/aos201333.0922002 Cite this Article Set citation alerts
    Chen Yang, Wang Yueming. Optical Design of Prism Spectrometer System with a Small Incident Angle[J]. Acta Optica Sinica, 2013, 33(9): 922002 Copy Citation Text show less
    References

    [1] Yu Bingxi. Research of high resolution imaging spectrometer [J]. Optics Mechanics and Electronics Information, 2000, 17(4): 1-5.

    [2] Wang Yueming, Lang Junwei, Wang Jianyu. Status and prospect of space-borne hyperspectral imaging technology[J]. Laser & Optoelectronics Process, 2013, 50(1): 010008

    [3] Yang Jin, Tang Yuguo, Bayanheshig, et al.. Design of Dyson concentric optical hyperspectral imaging system with achromatized Féry prism[J]. Acta Optica Sinica, 2012, 32(11): 1130003

    [4] Zheng Yuquan, Yu Bingxi. Overview of spectrum-dividing technologies in imaging spectrometers [J]. Remote Sensing, 2002, 6(1): 76-79.

    [5] Wang Yiqun, Yan Changxiang, Miao Chun′an. Choice of spectral splitting modes in space-borne hyper-spectralimager [J]. Chinese Journal of Optics and Applied Optics, 2009, 2(4): 304-308.

    [6] L G Cooka, J F Silnya. Imaging spectrometer trade studies: a detailed comparison of the offner-chrisp and reflective triplet optical design forms [C]. SPIE, 2010, 7813: 78130F

    [7] Wang Xin. Study About the Optical System of the Prism Hyperspectral Imaging Camera [D]. Shanghai: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 2010.

    CLP Journals

    [1] Liu Bing, Liu Ying, Li Can, Wang Jian, Li Chun, Sun Qiang. Design of Optical System for Miniature Visible/Near-Infrared Real-Time Imaging Spectrometer[J]. Acta Optica Sinica, 2015, 35(6): 630002

    [2] Ren Zhong, Liu Guodong, Huang Zhen. Development of a High Performance Micro-Spectrophotometer for Biochemical Analyzer[J]. Laser & Optoelectronics Progress, 2014, 51(11): 112202

    [3] Chen Hongfu, Gong Yan, Luo Cong, Peng Jiantao. Design of Prism-Grating Imaging Spectrometer with Eliminating Spectral Line Curvature[J]. Acta Optica Sinica, 2014, 34(9): 922004

    [4] Li Chuang, Xue Changxi, Yang Hongfang, Zhang Ran. Optical System Design of Electronic Endoscope Objective with Q-type Aspheres[J]. Acta Optica Sinica, 2017, 37(6): 622001

    Chen Yang, Wang Yueming. Optical Design of Prism Spectrometer System with a Small Incident Angle[J]. Acta Optica Sinica, 2013, 33(9): 922002
    Download Citation