• Acta Optica Sinica
  • Vol. 30, Issue 3, 821 (2010)
Ma Haotong*, Xi Fengjie, Zhou Pu, Xu Xiaojun, Chen Jinbao, and Liu Zejin
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos20103003.0821 Cite this Article Set citation alerts
    Ma Haotong, Xi Fengjie, Zhou Pu, Xu Xiaojun, Chen Jinbao, Liu Zejin. Measurement of M2 Factor of 1064 nm Pulsed Laser Based on Crossed Defocus Gratings[J]. Acta Optica Sinica, 2010, 30(3): 821 Copy Citation Text show less

    Abstract

    It is impossible to measure the M2 factor of pulsed laser effectively by using the traditional equipment. For real-time measurement of the M2 factor,two crossed defocus gratings and a lens with short focal length are used to obtain nine beam spots of different positions. The value of M2 factor is determined by calculating the beam waists using the second-moment method and curve-fitting. According to the theory of Gaussian beam propagation and transformation,measured errors as functions of beam waist and positions are analyzed. The analysis shows that the measuring system can work well in a large range. The pulse-to-pulse M2 factors and the change of M2 factors along with the pumping voltages of the 1064 nm Nd:罽AG pulsed laser are measured. The results indicate that measurements of M2 factor of pulsed laser are realized and the system can work successfully for measuring changes of M2 factors during laser working in real time.
    Ma Haotong, Xi Fengjie, Zhou Pu, Xu Xiaojun, Chen Jinbao, Liu Zejin. Measurement of M2 Factor of 1064 nm Pulsed Laser Based on Crossed Defocus Gratings[J]. Acta Optica Sinica, 2010, 30(3): 821
    Download Citation