• Photonic Sensors
  • Vol. 6, Issue 2, 127 (2016)
Hengyi LI*
Author Affiliations
  • Department of Electronic Information Engineering, Jincheng College of Sichuan University, 611731, Chengdu, China
  • show less
    DOI: 10.1007/s13320-015-0290-8 Cite this Article
    Hengyi LI. High Sensitivity Gas Sensor Based on IR Spectroscopy Technology and Application[J]. Photonic Sensors, 2016, 6(2): 127 Copy Citation Text show less
    References

    [1] J. Faist, F. Capasso, D. L. Sivco, C. Sirtori, A. L. Hutchinson, and A. Y. Cho, “Quantum cascade laser,” Science, 1994, 264(158): 553-556.

    [2] L. Wang and T. R. Sharples, “Intrapulse quantum cascade laser spectroscopy: pressure induced line broadening and shifting in the ν6 band of formaldehyde,” Applied Physics B, 2012, 108(2): 427-435.

    [3] T. Steck, N. Glatthor, T. von Clarmann, H. Fischer, J. M. Flaud, and B. Funke, “Retrieval of global upper tropospheric and stratospheric formaldehyde (H2CO) distributions from high-resolution MIPAS-envisat spectra,” Atmospheric Chemistry & Physics, 2008, 8(3): 463-470.

    [4] X. Chen, L. Cheng, D. Guo, Y. Kostov, and F. S. Choa, “Quantum cascade laser based standoff photoacoustic chemical detection,” Optics Express, 2011, 9(21): 20251-20257.

    [5] L. Wang and S. Thomas-Reoben, “Monitoring hydrogen sulfide using a quantum cascade laser based trace gas sensing system,” Chinese Physics Letters, 2011, 28(6): 1183-1187.

    [6] K. Chance and J. Orphal, “Revised ultraviolet absorption cross sections of H2CO for the HITRAN database,” Journal of Quantitative Spectroscopy & Radiative Transfer, 2011, 112(9): 1509-1510.

    [7] I. R. Burling, R. J. Yolelson, S. K. Akagi, S. P. Urbanski, C. E. Wold, D. W. T. Griffith, et al., “Airborne and ground-based measurements of the trace gases and particles emitted by prescribed fires in the United States,” Atmospheric Chemistry & Physics, 2011, 11(23): 12197-12216.

    [8] C. L. Heald, A. H. Goldstein, J. D. Allan, and A. C. Aiken, “Total observed organic carbon (TOOC) in the atmosphere: a synthesis of North American observations,” Atmospheric Chemistry & Physics, 2008, 8(7): 2007-2025.

    [9] L. Wang, “Formaldehyde and methane spectroscopy measurements based on mid-IR quantum cascade laser system,” Journal of Infrared and Millimeter Waves, 2014, 33(6): 591-597.

    [10] G. Duxbury, N. Langford, M. T. McCulloch, and W. Stephen, “Quantum cascade semiconductor infrared and far-infrared lasers: from trace gas sensing to non-linear optics,” Chemical Society Reviews, 2005, 34(11): 921-934.

    Hengyi LI. High Sensitivity Gas Sensor Based on IR Spectroscopy Technology and Application[J]. Photonic Sensors, 2016, 6(2): 127
    Download Citation