• Acta Optica Sinica
  • Vol. 32, Issue 2, 212007 (2012)
Xu Weiwei*, Zhang Liming, Yang Benyong, and Qiao Yanli
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201232.0212007 Cite this Article Set citation alerts
    Xu Weiwei, Zhang Liming, Yang Benyong, Qiao Yanli. On-Orbit Radiometric Calibration Based on Gray-Scale Tarps[J]. Acta Optica Sinica, 2012, 32(2): 212007 Copy Citation Text show less
    References

    [1] Zheng Xiaobing, Zhang Liming, Wu Haoyu et al.. Advanced radiometric calibration techniques for optical remote sensing[J]. Advances in Marine Science, 2004, 22(21): 16~22

    [2] Fu Qiaoyan, Min Xiangjun, Li Xingchao et al.. In-flight absolute calibration of the CBERS-02 CCD sensor at the Dunhuang test site[J]. J. Remote Sensing, 2006, 10(4): 433~439

    [3] Qiao Yanli, Zheng Xiaobing, Wang Xianhua et al.. Whole-process radiometric calibration of optical remote sensors[J]. J. Remote Sensing, 2006, 10(5): 606~623

    [4] P. N. Slater, S. F. Biggar, R. G. Holm et al.. Reflectance and radiance-based methods for the inflight absolute calibration of multispectral sensors[J]. Remote Sensing of Environment, 1987, 22(1): 11~37

    [5] S. F. Biggar. In-Flight Methods for Satellite Sensor Absolute Radiometric Calibration[D]. Tucson: The University of Arizona, 1990

    [6] S. F. Biggar, P. N. Slater, D. I. Gellman. Uncertainties in-flight calibration of sensors with reference to measured ground sites in the 0.4~1.1 μm range[J]. Remote Sensing of Environment, 1994, 48(2): 245~252

    [7] K. J. Thome. Absolute radiometric calibration of Landsat-7 ETM+ using the reflectance-based method[J]. Remote Sensing of Environment, 2001, 78(1-2): 27~38

    [8] P. N. Slater, S. F. Biggar, K. J. Thome et al.. Vicarious radiometric calibrations of EOS sensors[J]. J. Atmospheric and Oceanic Technology, 1996, 13(2): 349~359

    [9] K. J. Thome. Validation plan for MODIS level 1 at-sensor radiance[OL]. [2011-12-30]. http://modis.gsfc.nasa.gov/

    [10] Zhang Yuxiang, Zhang Guangshun, Huang Yibin et al.. In-flight vicarious radiometric calibration for VIS-NIR channels of FY-1C satellite sensor at Dunhuang site[J]. Acta Meteorologica Sinica, 2002, 60(6): 740~747

    [11] Hu Xiuqing, Zhang Yuxiang, Qiu Kangmu. In-flight radiometric calibration for VIR channels of FY-1C satellite sensor by using irradiance-based method[J]. J. Remote Sensing, 2003, 7(6): 458~464

    [12] Sun Jijuan, Ma Guoqiang, Zeng Yong et al.. Absolute radiometric calibration and the uncertainty analysis of CBERS-02 TIR band[J]. Spacecraft Recovery and Remote Sensing, 2007, 28(1): 33~38

    [13] K. Holekamp. Radiometric characterization of the IKONOS, QuickBird, and OrbView-3 sensors[R]. 2006 Civil Commercial Imagery Evaluation Workshop, 2006

    [14] M. Pagnutti. Atmospheric correction of high spatial resolution commonercial satellite imagery products using MODIS atmospheric products[C]. 3rd International Workshop on the Analysis of Multi-Temporal Remote Sensing Images, 2005

    [15] Xu Qiuyun, Zheng Xiaobing, Zhang Wei et al.. Advanced calibration method for sun radiometers[J]. Acta Optica Sinica, 2010, 30(5): 1337~1342

    [16] Yang Benyong, Zhang Liming, Yang Baoyun et al.. Space stability measurement and analysis of diffuser panel used for on-board calibration for satellite optical sensors[J]. Chinese J. Lasers, 2009, 36(11): 3026~3030

    [17] D. David, C. Nagur, Cherukuru et al.. Use of a spectralon panel to measure the downwelling irradiance signal: case studies and recommendations[J]. Appl. Opt., 2004, 43(20): 5981~5986

    CLP Journals

    [1] Chang Songtao, Zhang Yaoyu, Sun Zhiyuan, Zhu Wei. Radiation Measurement Method for Infrared Small Targets[J]. Acta Optica Sinica, 2014, 34(5): 504001

    [2] Guo Lingling, Wu Zepeng, Zhang Liguo, Zhang Xingxiang, Ren Jianyue. Destriping of Remote Sensing Images with Applications to Push-Broom-Type Cameras[J]. Acta Optica Sinica, 2013, 33(8): 828001

    [3] Wu Xingxing, Liu Jinguo, Zhou Huaide, Zhang Boyan. Automatic on-Orbit Adjusting Gains of Space Camera Based on Lighting Conditions[J]. Acta Optica Sinica, 2014, 34(3): 328001

    [4] Li Junlin, Zhang Liming, Chen Hongyao, Si Xiaolong, Wang Jixiang, Yang Baoyun, Shen Zhengguo. Development of BRDF Absolute Measuring Device[J]. Acta Optica Sinica, 2014, 34(5): 528002

    [5] Han Qijin, Pan Zhiqiang, Zhang Xuewen, Liu Li, Wang Aichun. Cross-calibration of GF-1 WFV and SJ-9A PMS Sensors Based on Homogeneous Land Surface Targets[J]. Acta Optica Sinica, 2014, 34(6): 628003

    [6] Han Qijin, Liu Li, Fu Qiaoyan, Zhang Xuewen, Wang Aichun, Pan Zhiqiang. Vicarious Calibration of Multiple Sensors Based on Reanalysis Data of Pseudo-Invariant Site[J]. Acta Optica Sinica, 2014, 34(11): 1128002

    [7] Xu Weiwei, Zhang Liming, Chen Hongyao, Li Xin, Yang Baoyun, Wang Jixiang. In-Flight Radiometric Calibration of High Resolution Optical Satellite Sensor Using Reflected Point Sources[J]. Acta Optica Sinica, 2017, 37(3): 328001

    [8] Han Qijin, Ma Lingling, Liu Li, Zhang Xuewen, Fu Qiaoyan, Pan Zhiqiang, Wang Aichun. On-Orbit Calibration and Evaluation of GF-2 Satellite Based on Wide Dynamic Ground Target[J]. Acta Optica Sinica, 2015, 35(7): 728003

    Xu Weiwei, Zhang Liming, Yang Benyong, Qiao Yanli. On-Orbit Radiometric Calibration Based on Gray-Scale Tarps[J]. Acta Optica Sinica, 2012, 32(2): 212007
    Download Citation