• Chinese Optics Letters
  • Vol. 13, Issue 5, 051301 (2015)
Chunhua Wei, Shuhua Yan*, Cunbao Lin, Zhiguang Du, and Guochao Wang
Author Affiliations
  • College of Mechatronic Engineering and Automation, National University of Defense Technology, Changsha 410073, China
  • show less
    DOI: 10.3788/COL201513.051301 Cite this Article Set citation alerts
    Chunhua Wei, Shuhua Yan, Cunbao Lin, Zhiguang Du, Guochao Wang. Compact grating displacement measurement system with a 3 × 3 coupler[J]. Chinese Optics Letters, 2015, 13(5): 051301 Copy Citation Text show less
    Schematic diagram of the system configuration. C, collimator.
    Fig. 1. Schematic diagram of the system configuration. C, collimator.
    Schematic diagram of signal processing module.
    Fig. 2. Schematic diagram of signal processing module.
    Measurement system; (a) schematic diagram of the measurement system; (b) picture of the prototype of the measurement system. HPI, Hewlett Packard interferometer; LS, laser source; PC, personal computer.
    Fig. 3. Measurement system; (a) schematic diagram of the measurement system; (b) picture of the prototype of the measurement system. HPI, Hewlett Packard interferometer; LS, laser source; PC, personal computer.
    Grating images; (a) by Zygo New View 700; (b) by SEM.
    Fig. 4. Grating images; (a) by Zygo New View 700; (b) by SEM.
    Output of three interference signals.
    Fig. 5. Output of three interference signals.
    Comparison measurement result of the 10 mm round-trip; (a) original displacement difference; (b) linear fitting and residual error for the forward movement; (c) linear fitting and residual error for the backward movement. Disp, displacement.
    Fig. 6. Comparison measurement result of the 10 mm round-trip; (a) original displacement difference; (b) linear fitting and residual error for the forward movement; (c) linear fitting and residual error for the backward movement. Disp, displacement.
    Comparison measurement result of 200 μm movement; (a) original displacement difference; (b) linear fitting and residual error for the movement.
    Fig. 7. Comparison measurement result of 200 μm movement; (a) original displacement difference; (b) linear fitting and residual error for the movement.
    Stability test results; (a) the system stability measurement results for our system and HP5530 for 300 s; (b) Allan deviation analysis of the measurement data.
    Fig. 8. Stability test results; (a) the system stability measurement results for our system and HP5530 for 300 s; (b) Allan deviation analysis of the measurement data.
    Chunhua Wei, Shuhua Yan, Cunbao Lin, Zhiguang Du, Guochao Wang. Compact grating displacement measurement system with a 3 × 3 coupler[J]. Chinese Optics Letters, 2015, 13(5): 051301
    Download Citation