• Acta Optica Sinica
  • Vol. 40, Issue 6, 0628002 (2020)
Heyu Xu1、2、*, Liming Zhang1, Xin Li1, Wenxin Huang1, Xiaolong Si1, Weiwei Xu1, Shule Ge3, Yanhua Zhao4, and Hao Wang4
Author Affiliations
  • 1Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031,China
  • 2University of Science of and Technology of China, Hefei, Anhui 230026, China
  • 3China Center for Resources Satellite and Application, Beijing 100094, China
  • 4Beijing Institute of Space Mechanics & Electricity, Beijing 100094, China;
  • show less
    DOI: 10.3788/AOS202040.0628002 Cite this Article Set citation alerts
    Heyu Xu, Liming Zhang, Xin Li, Wenxin Huang, Xiaolong Si, Weiwei Xu, Shule Ge, Yanhua Zhao, Hao Wang. A Relative Radiometric Calibration Method Based on Solar Diffuser Research for a Linear Array CCD Detector[J]. Acta Optica Sinica, 2020, 40(6): 0628002 Copy Citation Text show less
    References

    [1] Hartmut H H, Manning E M. Evaluation of the AIRS and CrIS relative radiometric calibration under cloudy conditions[J]. Proceedings of SPIE, 9218, 92180F(2014).

    [2] Wang M, Chen C C, Pan J et al. A relative radiometric calibration method based on the histogram of side-slither data for high-resolution optical satellite imagery[J]. Remote Sensing, 10, 381(2018).

    [3] Li H C, Song H F. A relative radiometric correction method for linear array push-broom imagery[J]. Proceedings of SPIE, 8194, 81941L(2011).

    [4] Byun Y, Han D. Relative radiometric normalization of bitemporal very high-resolution satellite images for flood change detection[J]. Journal of Applied Remote Sensing, 12, 026021(2018).

    [5] Zheng L L, Jin G, Qu H S et al. Non-uniformity correction for multi-channel TDI CCD imaging system in wide response range[J]. Acta Optica Sinica, 37, 1111001(2017).

    [6] Li X S, Liu H X, Sun J X et al. Relative radiometric calibration for space camera with optical focal plane assembly[J]. Acta Optica Sinica, 37, 0828006(2017).

    [7] Krause K S. Relative radiometric characterization and performance of the QuickBird high-resolution commercial imaging satellite[J]. Proceedings of SPIE, 5542, 35-44(2004).

    [8] Krause K S. QuickBird relative radiometric performance and on-orbit long term trending[J]. Proceedings of SPIE, 6296, 62960P(2006).

    [9] Markham B, Barsi J, Kvaran G et al. Landsat-8 Operational Land Imager Radiometric Calibration and Stability[J]. Remote Sensing, 6, 12275-12308(2014).

    [10] Zhang G, Li L T. A study on relative radiometric calibration without calibration field for YG-25[J]. Acta Geodaetica et Cartographica Sinica, 46, 1009-1016(2017).

    [11] Morfitt R, Barsi J, Levy R et al. Landsat-8 operational land imager (OLI) radiometric performance on-orbit[J]. Remote Sensing, 7, 2208-2237(2015).

    [12] Li H C, Man Y T. Relative radiometric calibration method based on linear CCD imaging the same region of non-uniform scene[J]. Proceedings of SPIE, 9299, 929906(2014).

    [13] Yan M, Wang Z Y, He S S et al. A method of relative radiometric correction for linear push-broom CCD Image without calibration device onboard[J]. Proceedings of SPIE, 8203, 820303(2011).

    [14] Anderson C, Naughton D, Brun A et al. Radiometric correction of Rapid Eye imagery using the on-orbit side-slither method. [C]∥Proceedings of SPIE, 8080, 818008(2011).

    [15] Pesta F, Bhatta S, Helder D et al. Radiometric non-uniformity characterization correction of Landsat 8 OLI earth imagery-based techniques[J]. Remote Sensing, 7, 430-446(2015).

    [16] Gerace A, Schott J, Gartley M et al. Ananalysis of the side slither on-orbit calibration technique using the DIRSIG model[J]. Remote Sensing, 6, 10523-10545(2014).

    [17] Pan Z Q, Gu X F, Liu G D et al. Relativeradiometric correction of CBERS-01 CCD data based on detector histogram matching[J]. Geomatics and Information Science of Wuhan University, 30, 925-927(2005).

    [18] Duan Y N, Zhang L F, Yan L et al. Relative radiometric correction methods for remote sensing images and their applicability analysis[J]. Journal of Remote Sensing, 18, 597-617(2014).

    [19] Xiong X, Che N, Xie Y et al. Four-years on-orbit spectral characterization results for Aqua MODIS reflective solar bands[J]. Proceedings of SPIE, 6361, 63610S(2006).

    [20] Xiong X X, Angal A, Sun J Q et al. On-orbit performance of MODIS solar diffuser stability monitor[J]. Journal of Applied Remote Sensing, 8, 083514(2014).

    [21] Olij C, Jos G, Henri G et al. Spectralon diffuser calibration for MERIS[J]. Proceedings of SPIE, 3221, 63-74(1997).

    [22] Zhao Y H, Dai L Q, Bai S J et al. Design andimplementation of full-spectrum spectral imager system[J]. Spacecraft Recovery & Remote Sensing, 39, 38-50(2018).

    [23] Yang B Y, Zhang L M, Shen Z G et al. Characteristic measurement of diffuser panel used for on-board calibration for satellite optical sensors[J]. Optics and Precision Engineering, 17, 1851-1858(2009).

    [24] Ge Z, Chen J J, Li Y D et al. Parameter test method for radiation damage of CCD[J]. Aerospace Shanghai, 32, 64-68(2015).

    Heyu Xu, Liming Zhang, Xin Li, Wenxin Huang, Xiaolong Si, Weiwei Xu, Shule Ge, Yanhua Zhao, Hao Wang. A Relative Radiometric Calibration Method Based on Solar Diffuser Research for a Linear Array CCD Detector[J]. Acta Optica Sinica, 2020, 40(6): 0628002
    Download Citation