• Acta Optica Sinica
  • Vol. 29, Issue 5, 1183 (2009)
Yang Jianchun1、2、*, Xu Longjun2, Zhang Peng1, and Chen Weimin1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article Set citation alerts
    Yang Jianchun, Xu Longjun, Zhang Peng, Chen Weimin. Sensing Characteristic of Optical Fiber Refractive Index Sensor Based on Core Diameter Mismatch[J]. Acta Optica Sinica, 2009, 29(5): 1183 Copy Citation Text show less
    References

    [1] Yu Shigang. Analysis on measurement of liquid refractive index[J]. Optical Instruments, 2007, 29(4): 1~6

    [2] Yu Shigang. Study on application of a novel optical fiber sensor[J]. Chin. J. Quant. Electron., 2004, 21(1): 64~67

    [3] Zhao Yong, Liao Yanbiao. Novel optical fiber sensor for simultaneous undersea temperature and salinity measurement[J]. Acta Optica Sinica, 2002, 22(10): 1241~1244

    [4] J. Villatoro, D. Monzón-Hernández, D. Talavera. High resolution refractive index sensing with cladded multimode tapered optical fibre[J]. Electron. Lett., 2004, 40(2): 106~107

    [5] P. Polynkin, A. Polynkin, N. Peyghambarian et al.. Evanescent field-based optical fiber sensing device for measuring the refractive index of liquids in microfluidic channels[J]. Opt. Lett., 2005, 30(11): 1273~1275

    [6] A. M. Cardenas-Valencia, R. H. Byrne, E. T. Steimle. Development of stripped- cladding optical fiber sensors for continuous monitoring—I. Theoretical study of a referencing method for measuring refractive indices of fluids[J]. Sens. Actuators B, Chem., 2006, 115(1): 178~188

    [7] I. Noiseux, W. Long, A. Cournoyer et al.. Simple fiber-optic-based sensors for process monitoring: An application in wine quality control monitoring[J]. Appl. Spectrosc., 2004, 58(8): 1010~1019

    [8] K. Schroeder, W. Ecke, R. Mueller et al.. A fibre Bragg grating refractometer[J]. Meas. Sci. Technol., 2001, 12(7): 757~764

    [9] Yun Binfeng, Chen Na, Cui Yiping. Ref ractive index sensing character is tics of fiber bragg grating based on cladding mode[J]. Acta Optica Sinica, 2006, 26(7): 1013~1015

    [10] H. J. Patrick, A. D. Kersey, F. Bucholtz. Analysis of the response of long period fiber gratings to external index of refraction[J]. J. Lightw. Technol., 1998, 16(9): 1606~1612

    [11] Chen Genxiang, Liu Chunning, Li Tangjun et al.. Study on long-period fiber gratings[J]. Acta Optica Sinica, 2000, 20(5): 624~628

    [12] J. Villatoro, D. Monzón-Hernández. Low-cost optical fiber refractive-index sensor based on core diameter mismatch[J]. J. Lightwave Technol., 2006, 24(3): 1409~1413

    [13] Yang Jianchun, Xu Longjun, Zhang Peng et al.. Review on optical fiber evanescent wave gas sensor[J]. Opt. Techn., 2008, 34(4): 562~567

    [14] D. Luna-Moreno, D. Monzón-Hernández, J. Villatoro et al.. Optical fiber hydrogen sensor based on core diameter mismatch and annealed Pd-Au thin films[J]. Sensors and Actuators B: Chemical, 2007, 125(1): 66~71

    [15] D. Monzón-Hernández, D. Luna-Moreno, J. Villatoro et al.. All-optical fiber hydrogen sensor based annealed Pd-Au sensing nanolayers[C]. Third European Workshop on Optical Fibre Sensors, SPIE, 2007, 6619: 66191F-1~66191F-4

    [16] D. Luna-Moreno, D. Monzón-Hernández. Effect of the Pd–Au thin film thickness uniformity on the performance of an optical fiber hydrogen sensor[J]. Applied Surface Science, 2007, 253(21): 8615~8619

    [17] Yang Jianchun, Xu Longjun, Zhang Peng et al.. An Optical Fiber Methane Gas Sensing System Based on Core Diameter Mismatch[P]. China Patent, CN101162197A, 2008.4

    CLP Journals

    [1] Sun Hao, Hu Manli, Qiao Xueguang, Rong Qiangzhou, Xiang Guanghua, Liang Lei, Xu Qinfang. Fiber Refractive Index Sensor Based on Fiber Core Mismatch Multimode Interference[J]. Chinese Journal of Lasers, 2012, 39(2): 205001

    [2] Tong Zhengrong, Wang Jieyu, Yang Xiufeng, Cao Ye. Simultaneous Measurement of Temperature and Strain Based on Core Diameter Mismatch and Fiber Bragg Grating[J]. Acta Optica Sinica, 2012, 32(12): 1206001

    [3] Tong Zhengrong, Han Wei, Cao Ye. Fiber Sensor for Simultaneous Measurement of Temperature and Refraction Index Based on Multimode Fiber Core-Offset[J]. Acta Optica Sinica, 2014, 34(1): 106004

    [4] Zhang Xiaokang, Ye Xiaojing, Chen Zhidong. Doubly Cladding Single-Mode Optical Fiber Sensors and its Application in Temperature and Humidity Sensing[J]. Acta Optica Sinica, 2011, 31(6): 606004

    Yang Jianchun, Xu Longjun, Zhang Peng, Chen Weimin. Sensing Characteristic of Optical Fiber Refractive Index Sensor Based on Core Diameter Mismatch[J]. Acta Optica Sinica, 2009, 29(5): 1183
    Download Citation