• Laser & Optoelectronics Progress
  • Vol. 57, Issue 19, 191903 (2020)
Jianchang Li1、2, Chenglong Wang1、*, Sen Wang1、2, and Tingting Sun1、2
Author Affiliations
  • 1National Engineering Research Center for Technology and Equipment Technology of Environmental Deposition, Lanzhou Jiaotong University, Lanzhou, Gansu 730070, China
  • 2Key Laboratory of Opto-Technology and Intelligent Control, Ministry of Education, Lanzhou Jiaotong University, Lanzhou, Gansu 730070, China
  • show less
    DOI: 10.3788/LOP57.191903 Cite this Article Set citation alerts
    Jianchang Li, Chenglong Wang, Sen Wang, Tingting Sun. Detection Method for Radiant Energy Flow Density on Condenser Heat-Absorbing Tube Surface[J]. Laser & Optoelectronics Progress, 2020, 57(19): 191903 Copy Citation Text show less
    Light spot energy flow distribution measurement device on collector tube surface of LFR system
    Fig. 1. Light spot energy flow distribution measurement device on collector tube surface of LFR system
    Schematic of basic measurement principle
    Fig. 2. Schematic of basic measurement principle
    Diagram of experimental device
    Fig. 3. Diagram of experimental device
    Surface of Lambertian target
    Fig. 4. Surface of Lambertian target
    Calibration test chart
    Fig. 5. Calibration test chart
    Transmissivity test chart of attenuation sheet
    Fig. 6. Transmissivity test chart of attenuation sheet
    Spot image
    Fig. 7. Spot image
    Gray image of spot image
    Fig. 8. Gray image of spot image
    Histogram of gray distribution of focus spot image
    Fig. 9. Histogram of gray distribution of focus spot image
    Split graph with a threshold of 20
    Fig. 10. Split graph with a threshold of 20
    Energy flow density distribution map of focus spot
    Fig. 11. Energy flow density distribution map of focus spot
    Projection distribution map of energy flow density of spot on target surface
    Fig. 12. Projection distribution map of energy flow density of spot on target surface
    Energy flow density distribution map of focus spot along x-direction
    Fig. 13. Energy flow density distribution map of focus spot along x-direction
    Test areaabcdefgh
    ER,i /(W·m-2)60026002601060156013600859985998
    Table 1. Test calibration result
    Jianchang Li, Chenglong Wang, Sen Wang, Tingting Sun. Detection Method for Radiant Energy Flow Density on Condenser Heat-Absorbing Tube Surface[J]. Laser & Optoelectronics Progress, 2020, 57(19): 191903
    Download Citation