• Chinese Optics Letters
  • Vol. 14, Issue 2, 021101 (2016)
Guangchao Ye1, Rongwei Fan1, Zhaodong Chen1, Xinrui Xu1, Ping He2, and Deying Chen1、*
Author Affiliations
  • 1National Key Laboratory of Science and Technology on Tunable laser, Harbin Institute of Technology, Harbin 150080, China
  • 2College of Foundation Science, Harbin University of Commerce, Harbin 150028, China
  • show less
    DOI: 10.3788/COL201614.021101 Cite this Article Set citation alerts
    Guangchao Ye, Rongwei Fan, Zhaodong Chen, Xinrui Xu, Ping He, Deying Chen. Effect of time bin size on accuracy of streak tube imaging lidar[J]. Chinese Optics Letters, 2016, 14(2): 021101 Copy Citation Text show less

    Abstract

    Streak tube imaging lidar (STIL) is an active imaging system that has a high range accuracy with the use of a pulsed laser transmitter and streak tube receiver to produce 3D range images. This work investigates the effect of the time bin size on the range accuracy of STIL systems based on the peak detection algorithm. The numerical simulation indicates that the time bin size has a significant effect on the range accuracy, resulting in a modified analytical estimate of the range error. An indoor experiment with a planar target is carried out to validate the theory that shows the linear relationship between the range error and the time bin size. Finer 3D depth images of a fist model are acquired by using a smaller time bin size and the best range error of 0.003 m is achieved with the optimal time bin size of 0.07 ns.
    σrange=0.6cτlaserSNR,(1)

    View in Article

    Δrange=c2(1Ni=1N(tit¯)2)1/2,(2)

    View in Article

    σrange=ktBincτlaserSNR,(3)

    View in Article

    σrange=3.94tBincτlaserSNR.(4)

    View in Article

    SNR=10lgIaverageσnoise,(5)

    View in Article

    Guangchao Ye, Rongwei Fan, Zhaodong Chen, Xinrui Xu, Ping He, Deying Chen. Effect of time bin size on accuracy of streak tube imaging lidar[J]. Chinese Optics Letters, 2016, 14(2): 021101
    Download Citation